Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 366 SW GASTONIA CT
FORT WHITE, FL 32038
Parcel #: 03950-005
Acres: 5.95
Owner: Soler Jimmy E
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 55282
Permit #: 000044726
Related Permit:
Submitted: Tuesday, June 21, 2022
Issued: Tuesday, June 21, 2022
Expires: Thursday, June 23, 2022
Completed: Thursday, June 23, 2022
Status: Completed
Septic Release? na
Notes:

Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 1624
No. of Stories 1
Ventilation: Unvented
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number fl4595.16r5
Product Manufacturer tri county
Product Description ultra rib
Sealed roof decking options: (Must select an option.) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.;a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.;two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0480C
Review Notes
6/21/2022 Permit Issued Permit #000044726 created and approved.
Contractors

This is an owner builder project.

Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - Final Anthony Aslan 6/23/2022