Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Additions Permit
Address 8797 SW OLD WIRE RD
FORT WHITE, FL 32038
Parcel #: 03930-000
Acres: 13.89
Owner: Morrison Michael Ardell, Morrison Heide Mendoza
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 54900
Permit #: 000044710
Related Permit:
Submitted: Wednesday, May 18, 2022
Issued: Friday, June 17, 2022
Expires: Saturday, November 11, 2023
Completed:
Status: Permit Issued
Septic Release? Yes
Notes:

Job Details
Is this an addition for commercial or residential use? Residential
Description of addition: 2 bedrooms, office, 1 full bathroom, 1/2 bath, closet
Total Estimated Cost 30000
Heated Area (Sqft) 917
Total Area (Sqft) 917
Stories 1
Building Height 12
Select driveway access to property: Existing Drive
Fire sprinklers? No
Building Code Construction Type V
Building Code Occupancy Types Residential
Building Code Element B
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setback Rear 25'
Septic# (00-0000) or (X00-000) 22-0459
Service Amps 200
Dev Permit # F023-
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Existing Building
Finished floor requirement Meet existing structure
Fema map number 12023C0480C
In floodway N
Sealed roof decking options. (Must select one.) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Review Notes
5/18/2022 Application pending.
5/19/2022 Point Review - Processing
5/27/2022 Point Review - Printed-Online Application NEEDED: *MANUAL J FORMS (?)-- TO BE DETERMINED UPON PLAN REVIEW *RESIDENTIAL CHECKLIST (?)-- TO BE DETERMINED UPON PLAN REVIEW *PRODUCT APPROVAL NUMBERS FOR EXTERIOR PRODUCTS (DOORS, WINDOWS, ROOF MATERIAL, ETC...) *SIGNED SUB VF FOR ALL TRADES *TRUSS ENGINEERING ***PRIOR TO INSPECTIONS*** RECORDED NOC
5/27/2022 Point Review - Reviewed NEEDED: *MANUAL J FORMS (?)-- TO BE DETERMINED UPON PLAN REVIEW *RESIDENTIAL CHECKLIST (?)-- TO BE DETERMINED UPON PLAN REVIEW *PRODUCT APPROVAL NUMBERS FOR EXTERIOR PRODUCTS (DOORS, WINDOWS, ROOF MATERIAL, ETC...) *SIGNED SUB VF FOR ALL TRADES *TRUSS ENGINEERING ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/2/2022 Point Review - Reviewed NEEDED: *MANUAL J FORMS *RESIDENTIAL CHECKLIST *PRODUCT APPROVAL NUMBERS FOR EXTERIOR PRODUCTS (DOORS, WINDOWS, ROOF MATERIAL, ETC...) *SIGNED SUB VF FOR ALL TRADES *TRUSS ENGINEERING ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/6/2022 Plan Review - On Hold-Incomplete NEEDED: *MANUAL J FORMS *RESIDENTIAL CHECKLIST *PRODUCT APPROVAL NUMBERS FOR EXTERIOR PRODUCTS (DOORS, WINDOWS, ROOF MATERIAL, ETC...) *SIGNED SUB VF FOR ALL TRADES *TRUSS ENGINEERING ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/8/2022 Plan Review - On Hold-Incomplete NEEDED: *RESIDENTIAL CHECKLIST *PRODUCT APPROVAL NUMBERS FOR EXTERIOR PRODUCTS ( WINDOWS, ROOF MATERIAL, ETC...) *SIGNED SUB VF FOR ALL TRADES ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/8/2022 Plan Review - Building Approved NEEDED: *RESIDENTIAL CHECKLIST ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/8/2022 Plan Review - Electrical Approved NEEDED: *RESIDENTIAL CHECKLIST ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/8/2022 Plan Review - Mechanical Approved NEEDED: *RESIDENTIAL CHECKLIST ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/8/2022 Plan Review - Plumbing Approved NEEDED: *RESIDENTIAL CHECKLIST ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/8/2022 Plan Review - Reviewed NEEDED: *RESIDENTIAL CHECKLIST ***PRIOR TO INSPECTIONS*** RECORDED NOC
6/14/2022 Zoning Review - Reviewed
6/16/2022 Final Review - Reviewed
6/17/2022 Final Review - Reviewed
6/17/2022 Final Review - Payment Needed
6/17/2022 Permit Issued Permit #000044710 created and approved.
Contractors

This is an owner builder project.

Name/ Business License Title Role
Ronald E Bonds Sr
Style Crest Inc
CAC1817658 Class "b" A/c Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 5/26/2022
Passed: Building - Footer Anthony Aslan 10/17/2022
Passed: Engineering - Setbacks Anthony Aslan 10/17/2022
Passed: Building - Vertical Cells/Columns Anthony Aslan 10/28/2022
Passed: Building - Framing Floor Framing & Strapping Anthony Aslan 12/14/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 12/14/2022
Cancelled: Building - Strapping Anthony Aslan 3/15/2023
Cancelled: Building - Wall Sheathing Anthony Aslan 3/15/2023
Passed: Building - Roof Decking Anthony Aslan 3/15/2023
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 3/15/2023
Failed: Building - Framing Engineer Letter Roof Framing In Place Of Engineered Trusses windows Not Installed Anthony Aslan 3/15/2023
Cancelled: Building - Wall Sheathing Matt Forsyth 5/3/2023
Passed: Building - Framing Matt Forsyth 5/3/2023
Passed: Building - Strapping Matt Forsyth 5/3/2023
Passed: Electrical - 1st Underground Rough–In Matt Forsyth 5/3/2023
Passed: Electrical - 2nd Rough-In Matt Forsyth 5/3/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 5/3/2023
Passed: Plumbing/Gas - Tub Set/Shower Pan Matt Forsyth 5/3/2023
Passed: Plumbing/Gas - Water Pipe Matt Forsyth 5/3/2023
Passed: Building - Insulation Matt Forsyth 5/15/2023