Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 717 SW EXPLORER GLN
FORT WHITE, FL 32038
Parcel #: 03816-106
Acres: 10.10
Owner: Wright Mary M
Subdivision: Crossroads Unr
Zoning: A-3
Flood Zone: X
District: 4
Application #: 55236
Permit #: 000044700
Related Permit:
Submitted: Thursday, June 16, 2022
Issued: Thursday, June 16, 2022
Expires: Tuesday, June 28, 2022
Completed: Tuesday, June 28, 2022
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Re-Cover - New Material over Existing
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 1720
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Repair Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Is the existing roof being removed? No
Explain if not removing the existing roofing material? metal over existing shingle
Type of New Roofing Product Metal
Florida Product Approval Number FL17992_R2_II_29 GA
Product Manufacturer Capital Metal
Product Description 29 gauge capital rib roof panel
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0485C
Review Notes
6/16/2022 Application pending.
6/16/2022 Point Review - Processing
6/16/2022 Final Review - Payment Needed
6/16/2022 Permit Issued Permit #000044700 created and approved.
Contractors
Name/ Business License Title Role
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 6/21/2022
Passed: Re-Roof - Final Anthony Aslan 6/28/2022