Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 265 SW FIELDSTONE CT
LAKE CITY, FL 32024
Parcel #: 02438-150
Acres: 0.51
Owner: Weatherly Glen Van, Weatherly Tavia
Subdivision: Emerald Cove Phase 2
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 54869
Permit #: 000044661
Related Permit: Culvert: 000044662
Submitted: Tuesday, May 17, 2022
Issued: Friday, June 10, 2022
Expires: Thursday, January 26, 2023
Completed: Thursday, January 26, 2023
Status: Completed
Septic Release? Yes
Notes:
LAKE CITY UTLITY CUSTOMER SERVICE NOTES THE CITY OF LAKE CITY DOES NOT PROVIDE UTILITIES TO THIS AREA. ELEVATION CONFIRMATION REC'D @ 143.70'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2105
Total Area (Sqft) 2807
Stories 1
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Septic# (00-0000) or (X00-000) 22-0426
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Subdivision Plat
Finished floor requirement 137'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
5/17/2022 City of Lake City Notified of Application within Utility Service Areas LC_GAS,.
5/18/2022 City of Lake City City of Lake City Approval Form submitted.
5/18/2022 Point Review - Received-Hard Copy Application NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/18/2022 Point Review - Reviewed NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/19/2022 Plan Review - Building Approved NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/19/2022 Plan Review - Electrical Approved NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/19/2022 Plan Review - Mechanical Approved NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/19/2022 Plan Review - Plumbing Approved NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/19/2022 Plan Review - Fuel/Gas Approved NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
5/26/2022 Zoning Review - Reviewed NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
6/6/2022 Final Review - Reviewed
6/6/2022 Final Review - Payment Needed
6/10/2022 Final Review - Payment Needed
6/10/2022 Permit Issued Permit #000044661 created and approved.
9/7/2022 Point Review - Reviewed
9/7/2022 Point Review - Reviewed
11/16/2022 Final Review - Payment Needed
11/16/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Mark Bauer
Gibraltar Contracting Llc
County License & State License & Liability Insurance & Employees Workers Comp Expired.
CBC1259633 Cert Building Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
CFC057960 Plumbing Contractor Subcontractor
Lewis G Walker
Lewis Walker Roofing Inc
CCC1333551 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Smith, Blake 6/14/2022
Passed: Building - Footer Matt Forsyth 6/22/2022
Passed: Engineering - Setbacks Matt Forsyth 6/22/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 7/13/2022
Passed: Building - Slab Troy Crews 7/19/2022
Passed: Electrical - Temporary Service Troy Crews 7/21/2022
Release to power company Troy Crews 7/21/2022
Passed: Building - Roof Decking Matt Forsyth 8/15/2022
Passed: Building - Wall Sheathing Matt Forsyth 8/15/2022
Passed: Building - Framing Troy Crews 9/1/2022
Passed: Electrical - 2nd Rough-In Troy Crews 9/1/2022
Passed: Mechanical - Rough In Troy Crews 9/1/2022
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 9/1/2022
Passed: Building - Insulation Walls And Some Ceiling Matt Forsyth 9/7/2022
Failed: Electrical - Permanent Power Undersized Bear Copper Ground Wire Septic And Drive Releases Matt Forsyth 11/18/2022
Failed: Engineering - Final Driveway No Limerock Cover Smith, Blake 11/21/2022
Passed: Electrical - Permanent Power Need Drive Release-- Do Not Issue Co Until Confirmation Rec'd From Sallie At Eh Even Though Septic Rec'd-- Mg Troy Crews 11/22/2022
Septic Release Inspection Do Not Issue Co Until Confirmation Rec'd From Sallie At Eh Even Though Septic Rec'd-- Mg Health Dept 11/22/2022
Passed: Engineering - Final Driveway Co Not To Be Given Until Driveway Is Complete Smith, Blake 11/23/2022
Release to power company Do Not Issue Co Until Confirmation Rec'd From Sallie At Eh Even Though Septic Rec'd-- Mg Melissa Garber 11/28/2022
Passed: Building - Final Waiting For Environmental Health--- Confirmation Rec'd 1/26/2023 Matt Forsyth 1/23/2023
Release to power company Melissa Garber 1/26/2023
Certificate-Release Certificate Matt Forsyth 1/26/2023
Documents
File Name Date File Size
Building Plans 2024-03-04 09.15.54.994.pdf 2024.03.04 25.42MB
Application Information Page 20220613 011851.pdf 2023.12.23 345.36kB
Power Release-release To Power Company 20230126.pdf 2023.12.23 38.95kB
44661 Plans.pdf 2023.12.23 30.52MB
Residential Or Commercial Checklist 20220613 012154.pdf 2023.12.23 2.18MB
Contractor Letter Of Authorization 20220613 012050.pdf 2023.12.23 331.76kB
50 Ec Roofing Affidavit 2022-06-02 17.32.38.441.pdf 2023.12.23 613.20kB
Lidar 54869 2022-05-26 10.29.46.507.pdf 2023.12.23 71.67kB
Subcontractor Form 20220613 011951.pdf 2023.12.23 1.19MB
Property Appraiser Parcel Details Printed Page 20220613 011947.pdf 2023.12.23 398.81kB
Power Release-electrical-temporary Service 20220721.pdf 2023.12.23 38.82kB
911 Address Form 20220613 012048.pdf 2023.12.23 271.74kB
Win_20230123_10_17_57_pro 2023-01-23 10.21.54.47.jpg 2023.12.23 122.16kB
Win_20230123_10_29_05_pro 2023-01-23 10.29.22.362.jpg 2023.12.23 287.77kB
Energy Code Forms 20220613 012548.pdf 2023.12.23 2.01MB
Emerald Cove Phs 2 2022-05-18 13.29.36.875.pdf 2023.12.23 1.09MB
Manual J Forms 20220613 012447.pdf 2023.12.23 1.40MB
Original Permit 20220610.pdf 2023.12.23 46.41kB
Certificate Of Occupancy 20230126.pdf 2023.12.23 69.06kB
City Of Lake City Approval Letter.pdf 2023.12.23 185.77kB
Surveyor Letter Giving The Finished Floor Elevation 44661 2022-08-12 09.38.37.754.pdf 2023.12.23 60.25kB
Power Release-release To Power Company 20221128.pdf 2023.12.23 38.95kB
Weatherly Eh 2022-06-02 17.17.39.853.pdf 2023.12.23 899.58kB
Site Plan 20220613 012049.pdf 2023.12.23 257.70kB
Truss Engineering 20220613 012450.pdf 2023.12.23 19.32MB
Owner And Contractor Signature Page 20220613 011949.pdf 2023.12.23 461.34kB