Permit Details

Permit Search

Permit

New Residential Construction

401 SW PINEHURST DR
LAKE CITY, FL 32024

Permit #
000044634
Application #
53988
Status Completed
  1. Submitted Apr 19, 2022
  2. Issued Jun 8, 2022
  3. Expires Oct 30, 2023
  4. Completed May 3, 2023

Property

Parcel #
03087-110
Owner
Alemany Luis Soto, Soto Maria L
Acres
0.67
Subdivision
Forest Country Sixth Addition
Zoning
RSF-2
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
93'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0289D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setbacks Rear
15'
Stories
1
Heated Area (Sqft)
2001
Total Area (Sqft)
2884
Building Height
21
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
22-0428
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps
200

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Plan Review - Corrections Needed
  5. Plan Review - Building Approved
  6. Plan Review - Electrical Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Reviewed
  10. Zoning Review - Reviewed
  11. Final Review - Documents Required
  12. Final Review - Documents Required
  13. Final Review - Documents Required
  14. Final Review - Documents Required
  15. Final Review - Payment Needed
  16. Final Review - Payment Needed
  17. Permit Issued
  18. Point Review - Reviewed
  19. Final Review - Payment Needed
  20. Final Review - Payment Needed

Contractors

  • Brian Papka

    Bp Building And Design Co

    License
    CBC1264659
    Title
    Cert. Building
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Donald Davis

    High Springs Electric Inc

    License
    EC0002306
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Ralph W Laverdure

    Rwl Roofing Llc

    License
    CCC1328590
    Title
    Roofing Contractor
    Role
    Subcontractor

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jul 19, 2022

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Jul 19, 2022

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Sep 2, 2022

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  4. Sep 14, 2022

    Passed: Building - Slab

    Fibermesh Concrete

    Inspected by Matt Forsyth

  5. Oct 11, 2022

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  6. Oct 11, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  7. Oct 11, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  8. Oct 11, 2022

    Passed: Building - Strapping

    Inspected by Matt Forsyth

  9. Oct 11, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  10. Dec 7, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  11. Dec 7, 2022

    Passed: Mechanical - Rough In

    Stove Vent Hasn't Been Installed

    Inspected by Matt Forsyth

  12. Dec 7, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Dec 21, 2022

    Passed: Building - Insulation

    Walls

    Inspected by Matt Forsyth

  14. Mar 29, 2023

    Failed: Electrical - Permanent Power

    Any Romex Running To The Panel Box Needs To Be Made-up Or Wire Nuts Installed. Also Need Septic Release

    Inspected by Matt Forsyth

  15. Apr 12, 2023

    Passed: Electrical - Permanent Power

    Need Septic And Driveway Released

    Inspected by Matt Forsyth

  16. Apr 18, 2023

    Septic Release Inspection

    Need Drive Release

    Inspected by Health Dept

  17. Apr 21, 2023

    Release to power company

    Inspected by Melissa Garber

  18. May 3, 2023

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents