Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 280 SW BLUE BIRD CT
FORT WHITE, FL 32038
Parcel #: 10070-118
Acres: 10.01
Owner: Christopher & Courtney Senter
Subdivision: Bluebird Landing Unr
Zoning: A-3
Flood Zone: X
District: 2
Application #: 54635
Permit #: 000044615
Related Permit:
Submitted: Tuesday, May 3, 2022
Issued: Friday, July 29, 2022
Expires: Tuesday, November 15, 2022
Completed: Tuesday, November 15, 2022
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0533C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2113
Total Area (Sqft) 3379
Building Height 24
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0395
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Service Amps 200
Review Notes
5/3/2022 Application pending.
5/4/2022 Point Review - Processing NEEDED * UPDATED LIABILITY FOR GERALD HARVEY * ROOF OPTION SELECTED
5/4/2022 Point Review - Processing NEEDED * UPDATED LIABILITY FOR GERALD HARVEY * ROOF OPTION SELECTED
5/5/2022 Point Review - Printed-Online Application NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *PRODUCT APPROVAL CODES *ENV HEALTH- CONTACT 386-758-1058 *TRUSS ENGINEERING
5/5/2022 Point Review - Reviewed NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *PRODUCT APPROVAL CODES *ENV HEALTH- CONTACT 386-758-1058 *TRUSS ENGINEERING
5/5/2022 Plan Review - Documents Required NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *PRODUCT APPROVAL CODES *ENV HEALTH- CONTACT 386-758-1058 *TRUSS ENGINEERING
5/17/2022 Plan Review - Building Approved NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/17/2022 Plan Review - Electrical Approved NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/17/2022 Plan Review - Mechanical Approved NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/17/2022 Plan Review - Plumbing Approved NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/17/2022 Plan Review - Fuel/Gas Approved NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/18/2022 Zoning Review - Reviewed NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/18/2022 Zoning Review - Reviewed NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/18/2022 Final Review - Documents Required NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *911 ADDRESS *ENV HEALTH- CONTACT 386-758-1058
5/23/2022 Final Review - Documents Required NEEDED *UPDATED LIABILITY FOR GERALD HARVEY *ROOF OPTION SELECTED *ENV HEALTH- CONTACT 386-758-1058
6/3/2022 Final Review - Payment Needed
6/6/2022 Permit Issued Permit #000044615 created and approved.
7/29/2022 Permit Reissued Permit reissued to reflect updated information.
10/12/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Gerald Harvey
Harvey Building & Construction Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CRC058134 Cert Residential Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
Robert M Bounds
Bounds Heating & Air Inc
CAC057642 Class A A/c Subcontractor
Wayne T Hodge
Hodge Plumbing Systems Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1426382 Plumbing Contractor Subcontractor
Dana D Johnson
Mac Johnson Roofing Inc Dba Gulf Coast Metal Roofing
CCC1325497 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 6/7/2022
Passed: Building - Slab Anthony Aslan 6/13/2022
Cancelled: Electrical - Temporary Service Emaleigh Williams 6/15/2022
Passed: Electrical - Temporary Service Anthony Aslan 6/15/2022
Release to power company Anthony Aslan 6/15/2022
Passed: Building - Roof Decking Anthony Aslan 7/5/2022
Failed: Building - Wall Sheathing Nails Missing Red Marker Anthony Aslan 7/5/2022
Passed: Building - Ext Strapping/Wall Sheathing Rec'd Pictures Anthony Aslan 7/6/2022
Passed: Building - Framing Anthony Aslan 7/6/2022
Passed: Mechanical - Rough In Dryer Pipe Can Not Be Diminished In Size Or Oval-shaped Anthony Aslan 7/29/2022
Passed: Electrical - 2nd Rough-In Anthony Aslan 7/29/2022
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 7/29/2022
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 7/29/2022
Cancelled: Mechanical - Rough In Anthony Aslan 8/1/2022
Passed: Building - Insulation Walls And Ceiling Bat Troy Crews 8/5/2022
Septic Release Inspection Health Dept 10/4/2022
Rescheduled 10/14/2022:Electrical - Permanent Power Emaleigh Williams 10/13/2022
Passed: Electrical - Permanent Power Anthony Aslan 10/14/2022
Release to power company Anthony Aslan 10/14/2022
Passed: Building - Final Anthony Aslan 11/15/2022
Documents
File Name Date File Size
Power Release-electrical-permanent Power 20221014.pdf 2025.07.05 11.68kB
Lidar 54635 2022-05-18 08.14.36.570.pdf 2025.07.05 88.65kB
Site Plan 20220503 181558.pdf 2025.07.05 69.97kB
Termite Certificate_final 20221017 081246.pdf 2025.07.05 134.74kB
Structural Analysis Report 20220614 082246.pdf 2025.07.05 145.89kB
Termite Treatment_initial 20220614 082346.pdf 2025.07.05 150.74kB
Blower Door Test Results 20221116 081047.pdf 2025.07.05 277.33kB
Subcontractor Form 20220503 181600.pdf 2025.07.05 168.03kB
Owner And Contractor Signature Page 20220503 174951.pdf 2025.07.05 261.74kB
Manual J Forms 20220503 181554.pdf 2025.07.04 814.08kB
Property Appraiser Parcel Details Printed Page 20220517 131901.pdf 2025.07.04 679.58kB
Energy Code Forms 20220503 175822.pdf 2025.07.04 1.83MB
Residential Or Commercial Checklist 54635 2022-05-05 14.31.01.881.pdf 2025.07.04 1.99MB
Certificate Of Occupancy 20221115.pdf 2023.12.26 44.02kB
Septic Approval Paperwork 20220516 173946.pdf 2023.12.23 1.17MB
Recorded Deed 20220503 174951.pdf 2023.12.23 278.23kB
Recorded Notice Of Commencement 20220503 175823.pdf 2023.12.23 256.43kB
911 Address Form 20220517 130418.pdf 2023.12.23 173.26kB
Truss Engineering 20220516 173948.pdf 2023.12.23 840.49kB
Architectural Plans 20220503 175821.pdf 2023.12.23 1.78MB
Approved Truss Engineering 54635 2022-05-17 10.36.47.581.pdf 2023.12.23 971.71kB
Product Approval Code Specifications Form 20220516 173941.pdf 2023.12.23 11.02MB
Approved Architectural Plans 54635 2022-05-05 14.27.22.215.pdf 2023.12.23 1.81MB
Senter Eh.pdf 2023.12.23 1.04MB
Updated Permit 20220729.pdf 2022.07.29 46.08kB
Power Release-electrical-temporary Service 20220615.pdf 2022.06.15 39.08kB
Original Permit 20220606.pdf 2022.06.06 46.03kB