Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Electrical Service Permit

Address 429 SW JAY GLN
FORT WHITE, FL 32038
Parcel #: 01439-761
Acres: 7.09
Owner: Thomas Susan, Thomas Wade Dillon
Subdivision: Wilson Springs Community Phase 4 Unr
Zoning: ESA-2
Flood Zone: AE
District: 2
Application #: 54500
Permit #: 000044259
Related Permit:
Submitted: Monday, April 25, 2022
Issued: Monday, April 25, 2022
Expires: Tuesday, April 26, 2022
Completed: Tuesday, April 26, 2022
Status: Completed
Septic Release? Yes
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0280D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove single layer of shingles /felt to expose decking for examination, re-nail decking to meet current code as needed, Provide/Install new 8" off ridge vents to replace existing, Reuse/reseal existing metal flashing details when possible, Provide/Install new factory painted galvanized eaves drip, Provide/Install OC WeatherLock on areas where pitch is below 4in12, P/I 2 layers of OC ProArmor synthetic underlayment, P/I OC WeatherLock Mat self-adhered leak barriers in valleys, P/I OC Starter Roll at eaves,P/I OC OakRidge Architectural shingles, P/I Oentsure Heat & Moisture Ridge Vent, P/I OC ProEdge hip and ridge cap, P/I new bullet boot pipe flashings and exhaust vent flashings
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 23059
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10674.1
Other Roofing Product Type Not Listed OC ProArmor Synthetic Underlayment Product Approval code 14299.1
Product Manufacturer Owens Corning
Product Description OC OakRidge Architectural
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
4/25/2022 Point Review - Processing
4/25/2022 Final Review - Payment Needed
4/25/2022 Permit Issued Permit #000044259 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Service Upgrade Final Matt Forsyth 4/26/2022
Release to power company Matt Forsyth 4/26/2022
Documents
File Name Date File Size