Inspection |
Notes |
Performed By |
Date |
Septic Release Inspection |
|
Health Dept |
3/30/2022 |
Passed: Engineering - Setbacks |
|
Anthony Aslan |
4/8/2022 |
Passed: Building - Footer |
|
Anthony Aslan |
4/8/2022 |
Rescheduled 4/22/2022:Plumbing/Gas - 1st Underground Rough–In |
|
Anthony Aslan |
4/21/2022 |
Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Anthony Aslan |
4/22/2022 |
Passed: Building - Slab |
|
Anthony Aslan |
4/25/2022 |
Passed: Electrical - Temporary Service |
|
Anthony Aslan |
4/28/2022 |
Release to power company |
|
Anthony Aslan |
4/28/2022 |
Cancelled: Building - Roof Decking |
|
Emaleigh Williams |
6/14/2022 |
Passed: Building - Roof Decking |
|
Anthony Aslan |
6/15/2022 |
Passed: Building - Wall Sheathing |
|
Troy Crews |
7/1/2022 |
Passed: Plumbing/Gas - 2nd Rough-In |
|
Troy Crews |
7/1/2022 |
Passed: Electrical - 2nd Rough-In |
|
Anthony Aslan |
7/21/2022 |
Cancelled: Building - Ext Strapping/Wall Sheathing |
|
Anthony Aslan |
7/21/2022 |
Cancelled: Building - Rated Assembly Fastening |
|
Anthony Aslan |
7/21/2022 |
Cancelled: Building - Strapping |
|
Anthony Aslan |
7/21/2022 |
Failed: Building - Framing |
Anchors Missing Bottom Plate And At Splices. Scuttle Hole Nothing Can Cross Opening |
Anthony Aslan |
7/21/2022 |
Failed: Mechanical - Rough In |
-dryer Pipe No Screws In Joints, Dryer Pipe Air Flow Wrong Direction, T-fin Not Allowed For Making 90's, Missing Nail Guard.
-bliability Insurance Expired.oot In A/c Room Not Sealed, 16" Flex Not Connected
-gaskets Missing On On Boots
-strapping Missing On Ducts
-tape Missing On Exhaust Pipe Over Living Room
|
Anthony Aslan |
7/21/2022 |
Cancelled: Building - Rated Assembly Fastening |
|
Anthony Aslan |
7/27/2022 |
Cancelled: Building - Ext Strapping/Wall Sheathing |
|
Anthony Aslan |
7/27/2022 |
Passed: Building - Framing |
Corrections Made |
Anthony Aslan |
7/27/2022 |
Failed: Mechanical - Rough In |
Dryer Pipe Not Corrected, Return Not Connected |
Anthony Aslan |
7/27/2022 |
Passed: Mechanical - Rough In |
Dryer Corrected, Return Picture Provided By A/c Contractor When Equipment Set |
Anthony Aslan |
8/2/2022 |
Passed: Building - Insulation |
Walls And Vaults.
no Exterior Doors Installed |
Anthony Aslan |
8/8/2022 |
Cancelled: Electrical - Temporary Service |
|
Anthony Aslan |
10/5/2022 |
Passed: Electrical - Permanent Power |
|
Anthony Aslan |
10/5/2022 |
Release to power company |
|
Anthony Aslan |
10/5/2022 |
Passed: Building - Final |
Fan In Half Bath Not Turning On By Switch |
Anthony Aslan |
12/6/2022 |