Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 236 SW CHESTERFIELD CIR
LAKE CITY, FL 32024
Parcel #: 03117-132
Acres: 0.50
Owner: Delta Omega Properties Inc
Subdivision: Crosswinds Phase 1
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 53996
Permit #: 000044020
Related Permit: Culvert: 000044022
Submitted: Wednesday, March 16, 2022
Issued: Monday, March 28, 2022
Expires: Wednesday, March 29, 2023
Completed: Wednesday, March 29, 2023
Status: Completed
Septic Release? Yes
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0313D
Type Roofing Job Overlay with Metal
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace wood as needed.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 41
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Metal roof over
Type of New Roofing Product Metal
Florida Product Approval Number FL17992.R2
Product Manufacturer Capital Metal Supply,INC.
Product Description 26 GA Rib
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) Other (explain)
Sealed roof decking explanation for other option. METAL ROOF OVER NO UNDERLAYMENT NEEDED
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
3/16/2022 Point Review - Received-Hard Copy Application
3/16/2022 Plan Review - Building Approved NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/16/2022 Plan Review - Electrical Approved NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/16/2022 Plan Review - Mechanical Approved NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/16/2022 Plan Review - Plumbing Approved NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/16/2022 Plan Review - Reviewed NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/23/2022 Zoning Review - Reviewed NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/24/2022 Zoning Review - Reviewed NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/24/2022 Final Review - Reviewed NOC - WILL BE NEEDED PRIOR TO FIRST INSPECTION!
3/24/2022 Final Review - Reviewed
3/24/2022 Final Review - Payment Needed
3/28/2022 Permit Issued Permit #000044020 created and approved.
9/20/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Brian T Giebeig
Trent Giebeig Construction,inc.
CRC1330693 Residential Contractor Contractor
Derrick L Williams
Dl Williams Heating & Cooling Llc
CAC1816913 Class "b" A/c Contractor Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Kenneth R Roche
Ken Roche Plumbing Inc Dba Plumbing Now
CFC1426527 Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Smith, Blake 3/29/2022
Passed: Building - Footer Matt Forsyth 4/20/2022
Passed: Engineering - Setbacks Matt Forsyth 4/20/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 4/28/2022
Passed: Building - Wall Sheathing Matt Forsyth 7/27/2022
Passed: Building - Roof Decking Matt Forsyth 7/27/2022
Passed: Building - Framing Matt Forsyth 7/29/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 8/11/2022
Failed: Mechanical - Rough In Need Gasket On All Penatrations Matt Forsyth 8/11/2022
Failed: Plumbing/Gas - 2nd Rough-In No Pressure On Supply , Need Relieving Arch On Water Supply For Outside Faucet Matt Forsyth 8/11/2022
Failed: Plumbing/Gas - Tub Set/Shower Pan Need Water In Tub Matt Forsyth 8/11/2022
Passed: Building - Insulation Walls Only Matt Forsyth 8/16/2022
Passed: Mechanical - Rough In Item Addressed Matt Forsyth 8/16/2022
Passed: Plumbing/Gas - 2nd Rough-In Item Addressed Matt Forsyth 8/16/2022
Passed: Electrical - Permanent Power Need Septic And Driveway To Complete Matt Forsyth 9/21/2022
Passed: Electrical - Permanent Power Need Septic And Driveway Matt Forsyth 10/3/2022
Release to power company Melissa Garber 10/5/2022
Passed: Engineering - Final Driveway Smith, Blake 10/5/2022
Septic Release Inspection Health Dept 10/5/2022
Certificate-Release Certificate Recv'd Picture Anthony Aslan 3/29/2023
Passed: Building - Final No Disconnect On Ahu And Water Heater (recv'd) Anthony Aslan 3/29/2023
Documents