New Residential Construction
Permit
| Application #: | 53912 |
| Permit #: |
000043912 |
| Related Permit: |
|
| Submitted: | Friday, March 11, 2022 |
| Issued: | Monday, March 14, 2022 |
| Expires: | Monday, October 2, 2023 |
| Completed: | Monday, October 2, 2023 |
| Status: |
Completed |
| Septic Release? |
Yes |
Job Details
| Elevation regulation |
Minimum Requirement |
| Finished floor requirement |
One foot above the road |
| Fema map number |
12023C0310C |
| Setbacks Front |
30' |
| Setback Side 1 |
25' |
| Setback Side 2 |
25' |
| Setbacks Rear |
25' |
| Stories |
1 |
| Heated Area (Sqft) |
1792 |
| Total Area (Sqft) |
1792 |
| Building Height |
15 |
| Building Code Construction Type |
V |
| Building Code Element |
B |
| Building Code Occupancy Types |
Residential |
| Occupancy Use Title |
single family dwelling |
| Building Code Edition |
2020 Florida Building Code 7th Edition and 2017 National Electrical Code |
| Septic# (00-0000) or (X00-000) |
22-0060 |
| Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) |
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof. |
| Service Amps |
200 |
Review Notes
| 3/11/2022 |
Point Review - Received-Hard Copy Application |
| 3/11/2022 |
Point Review - Reviewed |
| 3/13/2022 |
Plan Review - Plumbing Approved |
| 3/13/2022 |
Plan Review - Mechanical Approved |
| 3/13/2022 |
Plan Review - Electrical Approved |
| 3/13/2022 |
Plan Review - Building Approved |
| 3/13/2022 |
Plan Review - Reviewed |
| 3/13/2022 |
Zoning Review - Reviewed |
| 3/13/2022 |
Final Review - Corrections Needed |
| 3/13/2022 |
Final Review - Corrections Needed |
| 3/14/2022 |
Final Review - Payment Needed |
| 3/14/2022 |
Permit Issued |
| 9/28/2022 |
Final Review - Payment Needed |
Contractors
| Name / Business |
License |
Title |
Role |
Marcus Matthews Matthews Electric Llc
|
EC13005459 |
Electrical Contractor |
Subcontractor |
Rodney L Cribbs Quality Air Care Llc
|
RA13067616 |
Reg. A/c Class “b” |
Subcontractor |
Cody Barrs Barrs Plumbing Inc
|
CFC1427145 |
Plumbing Contractor |
Subcontractor |
Mary C Johnson Rcra Johnson Roofing,inc.
|
CCC1330073 |
Roofing Contractor |
Subcontractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Passed: Building - Footer |
|
Troy Crews |
3/22/2022 |
| Passed: Engineering - Setbacks |
|
Troy Crews |
3/22/2022 |
| Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Troy Crews |
4/6/2022 |
| Passed: Building - Slab |
|
Troy Crews |
4/12/2022 |
| Passed: Building - Roof Decking |
|
Troy Crews |
5/13/2022 |
| Passed: Building - Wall Sheathing |
|
Troy Crews |
5/13/2022 |
| Passed: Building - Framing |
|
Troy Crews |
7/20/2022 |
| Passed: Mechanical - Rough In |
|
Troy Crews |
7/20/2022 |
| Passed: Plumbing/Gas - 2nd Rough-In |
|
Troy Crews |
7/20/2022 |
| Passed: Electrical - 1st Underground Rough–In |
|
Troy Crews |
7/20/2022 |
| Passed: Building - Insulation |
|
Troy Crews |
8/4/2022 |
| Passed: Electrical - Permanent Power |
Need Septic Final
received 9.30.22 |
Troy Crews |
9/29/2022 |
| Release to power company |
Received Eh 9.30.22 |
Troy Crews |
9/30/2022 |
| Septic Release Inspection |
|
Health Dept |
10/4/2022 |
| Certificate-Release Certificate |
Assesments Paid |
Troy Crews |
10/2/2023 |
| (Requested) Building-Final |
|
|
|