Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 664 SW APPALACHEE TER
FORT WHITE, FL 32038
Parcel #: 03766-106
Acres: 10.01
Owner: Turner Michael, Turner Carrie
Subdivision: Appalachie Trace Unr
Zoning: A-3
Flood Zone: X
District: 4
Application #: 53236
Permit #: 000043677
Related Permit:
Submitted: Tuesday, January 25, 2022
Issued: Wednesday, February 9, 2022
Expires: Monday, October 31, 2022
Completed: Monday, October 31, 2022
Status: Completed
Septic Release? Yes
Notes:
MECHANICAL AT INWULATION SPACE AT SUPPLY & RETURN PLENUMS
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0480C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1600
Total Area (Sqft) 2210
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 22-0073
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
1/25/2022 Application pending.
1/31/2022 Point Review - Printed-Online Application
1/31/2022 Plan Review - Building Approved NEEDED: EH PAPERWORK
1/31/2022 Plan Review - Electrical Approved NEEDED: EH PAPERWORK
1/31/2022 Plan Review - Mechanical Approved NEEDED: EH PAPERWORK
1/31/2022 Plan Review - Plumbing Approved NEEDED: EH PAPERWORK
1/31/2022 Plan Review - Reviewed NEEDED: EH PAPERWORK
2/1/2022 Zoning Review - Reviewed NEEDED: EH PAPERWORK
2/1/2022 Final Review - Documents Required BUZBEE: NEEDED: EH PAPERWORK OWNER /CONTRACTOR SIGNATURE PAGE IS NEEDED!! - IT IS BLANK!! - PLEASE GATHER SIGNATURES & RE-UPLOAD
2/9/2022 Final Review - Payment Needed
2/9/2022 Permit Issued Permit #000043677 created and approved.
8/9/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Joel G Buzbee
G Buzbee, Inc
Workers Comp Expired.
CGC061980 Cert General Contractor
Paul K Coleman
Colemans Plumbing Inc.
CFC1425624 Certified Plumbing Subcontractor
Chad White
Ck Electric Llc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
EC13002222 Electrical Contractor Subcontractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Setbacks Anthony Aslan 2/23/2022
Passed: Building - Footer Anthony Aslan 2/23/2022
Failed: Electrical - Temporary Service Electrical Contractor Does Not Have Temporary Power Built Matt Forsyth 2/28/2022
Passed: Electrical - Temporary Service Anthony Aslan 3/2/2022
Release to power company Anthony Aslan 3/2/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 3/18/2022
Passed: Building - Slab Anthony Aslan 3/29/2022
Cancelled: Building - Roof Decking Anthony Aslan 5/4/2022
Failed: Building - Framing Not Finished, Beams On Porch Nailed 10"on Top And Bottom Dormers Not Complete Matt Forsyth 5/4/2022
Failed: Building - Roof Decking Matt Forsyth 5/4/2022
Passed: Building - Wall Sheathing Matt Forsyth 5/4/2022
Passed: Building - Roof Decking Matt Forsyth 5/6/2022
Failed: Building - Framing Need Truss Piggyback 4' Scab Tying Top Cord Of Trusses Together. Gable Strapping Needed Matt Forsyth 5/13/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 5/26/2022
Failed: Mechanical - Rough In Need 3inch Clearance Around Plenum Matt Forsyth 5/26/2022
Failed: Plumbing/Gas - 2nd Rough-In Need Pressure On Gas And Water Supply Matt Forsyth 5/26/2022
Passed: Plumbing/Gas - Tub Set/Shower Pan Tub Water Tested Matt Forsyth 5/26/2022
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 6/13/2022
Passed: Building - Framing Anthony Aslan 6/13/2022
Passed: Electrical - 2nd Rough-In Anthony Aslan 6/13/2022
Passed: Building - Insulation Dormer Windows Not Foamed, A/c Duct Over Attic Access Needs To Be Moved Anthony Aslan 6/23/2022
Passed: Electrical - Permanent Power Need Septic Release Matt Forsyth 8/10/2022
Release to power company Melissa Garber 9/1/2022
Septic Release Inspection Health Dept 9/1/2022
Passed: Building - Final Outlet Right Of Stove Hot/neutral Reversed Anthony Aslan 10/31/2022
Documents
File Name Date File Size
Lidar 53236 2022-02-01 09.37.42.634.pdf 2025.07.05 122.31kB
Product Approval Code Specifications Form 20220125 175302.pdf 2025.07.05 143.65kB
Termite Treatment_initial 20220330 081246.pdf 2025.07.05 112.82kB
911 Address Form 20220125 175300.pdf 2025.07.05 202.13kB
Manual J Forms 20220125 175302.pdf 2025.07.05 113.95kB
Blower Door Test Results 20221103 111046.pdf 2025.07.05 262.37kB
Structural Analysis Report 20220330 081147.pdf 2025.07.05 255.73kB
Subcontractor Form 20220125 175305.pdf 2025.07.04 684.26kB
Approved Structural Engineering And Wind Load Calculations 53236 2022-01-31 12.32.47.906.pdf 2025.07.04 1.96MB
Final Termite 43677 2022-10-31 12.05.02.751.jpg 2025.06.20 70.85kB
Architectural Plans 20220125 175301.pdf 2023.12.23 194.02kB
Energy Code Forms 20220125 175301.pdf 2023.12.23 1.01MB
Property Appraiser Parcel Details Printed Page 20220125 175303.pdf 2023.12.23 1.39MB
Approved Architectural Plans 53236 2022-01-31 12.32.48.531.pdf 2023.12.23 235.41kB
Approved Truss Engineering 53236 2022-01-31 12.32.47.203.pdf 2023.12.23 1.92MB
Residential Or Commercial Checklist 20220125 175304.pdf 2023.12.23 1.65MB
Recorded Deed 20220125 170351.pdf 2023.12.23 393.29kB
Truss Engineering 20220125 175306.pdf 2023.12.23 1.81MB
Owner And Contractor Signature Page 20220201 104016.pdf 2023.12.23 427.23kB
Septic Approval Paperwork 20220209 093028.pdf 2023.12.23 1.27MB
Structural Engineering And Wind Load Calculations 20220125 175304.pdf 2023.12.23 1.93MB
Site Plan 20220125 175304.pdf 2023.12.23 26.64kB
Recorded Notice Of Commencement 20220125 175303.pdf 2023.12.23 88.00kB
Certificate Of Occupancy 20221031.pdf 2022.10.31 62.23kB
Power Release-release To Power Company 20220901.pdf 2022.09.01 39.05kB
Power Release-electrical-temporary Service 20220302.pdf 2022.03.02 38.90kB
Original Permit 20220209.pdf 2022.02.09 45.21kB