Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 720 NW BAUGHN ST
LAKE CITY, FL 32055
Parcel #: 01771-101
Acres: 2.50
Owner: Kuklo Christine, Armstrong Michael
Subdivision: Country Lane Estates
Zoning: A-3
Flood Zone: X
District: 1
Application #: 53363
Permit #: 000043650
Related Permit:
Submitted: Thursday, February 3, 2022
Issued: Thursday, February 3, 2022
Expires: Friday, February 25, 2022
Completed: Friday, February 25, 2022
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0187D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 3800
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10124
Product Manufacturer GAF
Product Description TIMBERLINE
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Second Roof Pitch (if applicable) 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
2/3/2022 Application pending.
2/3/2022 Final Review - Payment Needed
2/3/2022 Permit Issued Permit #000043650 created and approved.
Contractors
Name/ Business License Title Role
Lewis G Walker
Lewis Walker Roofing Inc
CCC1333551 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 2/23/2022
Passed: Re-Roof - Final Troy Crews 2/25/2022