- Finished floor requirement
-
- Fema map number
- 12023C0285D
- Type Roofing Job
- Re-Cover - New Material over Existing
- Further Job Details (Explain if decking is being replaced and or Repairs are being done.)
- Existing R-Panel Metal building. New roof to be, EPS insulation Flute Fill, 1?2" Densdeck gypsum cover board, and a mechanically attached 60 mil TPO
- Type of structure
- Commercial Building
- Commercial or Residential
- Commercial
- Roof Area (for this job) Sq Ft
- 10000
- No. of Stories
- 1
- Roof Pitch
- Less than 2:12
- Is the existing roof being removed?
- No
- Explain if not removing the existing roofing material?
- R-Panel Metal Building. New roof to overlay R-Panel
- Type of New Roofing Product
- Flat or Membrane type
- Florida Product Approval Number
- FL14083-R26
- Product Manufacturer
- Carlisle
- Product Description
- Mechanically Fastened TPO
- Building Code Edition
- 2020 Florida Building Code 7th Edition and Florida Statute 553.844
- Sealed roof decking options: (Must select an option.)
- Other (explain)
- Sealed roof decking explanation for other option.
- New TPO roof system to completely cover existing metal roof
- Ventilation:
- Unvented