Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 169 SW VERMONT WAY
LAKE CITY, FL 32025
Parcel #: 08107-026
Acres: 0.49
Owner: Lee Deborah D
Subdivision: Edgewood Estates
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 53158
Permit #: 000043566
Related Permit:
Submitted: Wednesday, January 19, 2022
Issued: Thursday, January 20, 2022
Expires: Thursday, July 7, 2022
Completed: Thursday, July 7, 2022
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0292D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2500
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number Fl-10124-R16
Product Manufacturer Gaf
Product Description 30 Year Architectural Shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
1/19/2022 Application pending.
1/19/2022 City of Lake City City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER,.
1/20/2022 Final Review - Payment Needed
1/20/2022 Permit Issued Permit #000043566 created and approved.
Contractors
Name/ Business License Title Role
Darin L Summerlin
Summerlin Roofing Inc
CCC1326192 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Roof Mostly Complete Need Ridge Vent Anthony Aslan 1/31/2022
Passed: Re-Roof - Final Anthony Aslan 7/7/2022