Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 290 SW BARON GLN
FORT WHITE, FL 32038
Parcel #: 03752-438
Acres: 4.77
Owner: Johnson Marcus Marice, Johnson Candace Tiara
Subdivision: Southern Meadows Phase 1
Zoning: A-3
Flood Zone: X
District: 4
Application #: 52943
Permit #: 000043488
Related Permit:
Submitted: Wednesday, December 22, 2021
Issued: Friday, January 7, 2022
Expires: Monday, November 21, 2022
Completed: Monday, November 21, 2022
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D @ 82.72'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 81'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0390C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2186
Total Area (Sqft) 3065
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-1038
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Review Notes
12/22/2021 Point Review - Received-Hard Copy Application NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
12/22/2021 Point Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
12/22/2021 Zoning Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ROOF OPTION SELECTED
12/30/2021 Plan Review - Building Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ROOF OPTION SELECTED
12/30/2021 Plan Review - Electrical Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ROOF OPTION SELECTED
12/30/2021 Plan Review - Mechanical Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ROOF OPTION SELECTED
12/30/2021 Plan Review - Plumbing Approved NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ROOF OPTION SELECTED
12/30/2021 Plan Review - Reviewed NEEDED: *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ROOF OPTION SELECTED
1/6/2022 Final Review - Reviewed
1/6/2022 Final Review - Payment Needed
1/7/2022 Permit Issued Permit #000043488 created and approved.
11/4/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
William S Crawford
Stanley Crawford Construction Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
RG0042896 General Contractor Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
Workers Comp Expired.
CAC1819412 Cert. A/c Class “b” Subcontractor
Kenneth Ault
Kenneth Edward Ault Plumbing Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1429807 Cert. Plumbing Subcontractor
Ralph W Laverdure
Rwl Roofing Llc
CCC1328590 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 1/13/2022
Passed: Engineering - Setbacks Matt Forsyth 1/13/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 1/28/2022
Passed: Building - Slab Fiber Mesh Concrete Matt Forsyth 2/1/2022
Passed: Electrical - Temporary Service Matt Forsyth 2/10/2022
Release to power company Matt Forsyth 2/10/2022
Passed: Building - Wall Sheathing Matt Forsyth 3/18/2022
Passed: Building - Roof Decking Matt Forsyth 4/18/2022
Passed: Building - Wall Sheathing Windstorm Osb Matt Forsyth 4/18/2022
Passed: Building - Framing Matt Forsyth 5/19/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 5/19/2022
Failed: Mechanical - Rough In Need 3inch Clearance Around Ductwork In Ahu Closet Matt Forsyth 5/19/2022
Passed: Plumbing/Gas - 2nd Rough-In Need Water Test On Tubs Matt Forsyth 5/19/2022
Passed: Mechanical - Rough In Matt Forsyth 5/25/2022
Passed: Plumbing/Gas - Tub Set/Shower Pan Tub Water Tested Matt Forsyth 5/25/2022
Passed: Building - Insulation Need To Get Doors In Asap, Or Cover Openings Temporary. Troy Crews 6/6/2022
Passed: Electrical - Permanent Power Need Septic Matt Forsyth 10/24/2022
Release to power company Melissa Garber 10/27/2022
Septic Release Inspection Health Dept 10/27/2022
Failed: Building - Final Kitchen Countertops Require Two Branch Circuits For Receptacles Need Blower Door Test Dining Room Sliding Door Not Locking Matt Forsyth 11/17/2022
Passed: Building - Final Troy Crews 11/21/2022