Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 957 SW TRULUCK TER
FORT WHITE, FL 32038
Parcel #: 04348-003
Acres: 20.00
Owner: Lessard Wayne B, Lessard Jennifer D
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 52945
Permit #: 000043444
Related Permit:
Submitted: Wednesday, December 22, 2021
Issued: Friday, January 7, 2022
Expires: Friday, May 27, 2022
Completed: Friday, May 27, 2022
Status: Completed
Septic Release? na
Notes:
PICS REC'D
Job Details
Type Roofing Job Re-Cover - New Material over Existing
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 44.00
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? No
Explain if not removing the existing roofing material? Installing Standing Seam Metal over existing Roof.
Type of New Roofing Product Metal
Florida Product Approval Number 23302.1
Product Manufacturer Tri County Metals
Product Description Max 15.75" wide, 26 ga. concealed fastener roof panel over min 15/32" thick plywood deck or 7/16" thick OSB.
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0533C
Review Notes
12/22/2021 Application pending.
12/22/2021 Final Review - Corrections Needed NEEDED: *OWNERS PHONE NUMBER ***PRIOR TO INSPECTIONS*** RECORDED TO NOC
12/23/2021 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED TO NOC
12/23/2021 Permit Issued Permit #000043444 created and approved.
1/7/2022 Permit reissued to reflect updated information.
Contractors
Name/ Business License Title Role
Robert Tracey
Bobby's Roofing Of Th Florida Keys, Inc.
County License & State License & Liability Insurance & Workers Comp Expired.
CCC1325524 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Roof Completed Anthony Aslan 5/25/2022
Passed: Re-Roof - Final Anthony Aslan 5/27/2022