Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 276 SW RIVERSIDE AVE
FORT WHITE, FL 32038
Parcel #: 00533-007
Acres: 1.15
Owner: Baker James Dudley, Stock Alexandra
Subdivision: Three Rivers Estates Unit 1
Zoning: ESA-2
Flood Zone: AE
District: 2
Application #: 52447
Permit #: 000043380
Related Permit:
Submitted: Sunday, November 7, 2021
Issued: Tuesday, December 14, 2021
Expires: Friday, September 1, 2023
Completed: Friday, September 1, 2023
Status: Completed
Septic Release? Yes
Notes:
CHECK 12.8' SIDE SETBACK - SEE SURVEY SITE PLAN
Job Details
Elevation regulation Special Flood Hazard Area
Finished floor requirement 34' One foot above FEMA Map Elevation
Requirement needed By Permanent Power Inspection
Document needed is an Elevation Certificate for Finished Construction
Document receieved Yes
Fema map number 12023C0458C
Water source Itchetucknee
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1150
Total Area (Sqft) 1472
Building Height 32
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0823
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Service Amps 200
Review Notes
11/8/2021 Point Review - Received-Hard Copy Application NEEDED: *DRIVEWAY ACCESS? *911 ADDRESS VERIFICATION *ONE FOOT RISE-- COMPLETED BY AN ENGINEER *PRODUCT APPROVAL #S *RESIDENTIAL CHECKLIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ENERGY CODE AND MANUAL J FORMS *TRUSS ENGINEERING
11/8/2021 Point Review - Reviewed NEEDED: *DRIVEWAY ACCESS? *911 ADDRESS VERIFICATION *ONE FOOT RISE-- COMPLETED BY AN ENGINEER *PRODUCT APPROVAL #S *RESIDENTIAL CHECKLIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ENERGY CODE AND MANUAL J FORMS *TRUSS ENGINEERING
11/10/2021 Plan Review - Documents Required NEEDED: *911 ADDRESS VERIFICATION *ONE FOOT RISE-- COMPLETED BY AN ENGINEER *PRODUCT APPROVAL #S *RESIDENTIAL CHECKLIST *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 *ENERGY CODE AND MANUAL J FORMS *TRUSS ENGINEERING
11/30/2021 Plan Review - Building Approved
11/30/2021 Plan Review - Electrical Approved
11/30/2021 Plan Review - Mechanical Approved
11/30/2021 Plan Review - Plumbing Approved
11/30/2021 Plan Review - Reviewed
12/8/2021 Zoning Review - Reviewed
12/8/2021 Final Review - Complete
12/8/2021 Final Review - Payment Needed
12/14/2021 Permit Issued Permit #000043380 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 12/9/2021
Passed: Building - Footer Matt Forsyth 12/29/2021
Passed: Engineering - Setbacks Matt Forsyth 12/29/2021
Passed: Building - Vertical Cells/Columns Matt Forsyth 2/2/2022
Cancelled: Engineering - Spot Check Melissa Garber 9/26/2022
Passed: Engineering - Spot Check Partial Floor Framing Matt Forsyth 9/26/2022
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 10/31/2022
Passed: Building - Framing Need Handrail Complete With H25s Strapping On Porch Matt Forsyth 12/13/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 3/22/2023
Passed: Mechanical - Rough In Matt Forsyth 3/22/2023
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 3/22/2023
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 3/22/2023
Passed: Building - Insulation Matt Forsyth 4/3/2023
Passed: Electrical - Permanent Power Need Elevation Certificate Matt Forsyth 7/28/2023
Electrical -Permanent Power Elevation Certificate Recieved Troy Crews 8/8/2023
Release to power company Troy Crews 8/8/2023
Certificate-Release Certificate Matt Forsyth 9/1/2023
Passed: Building - Final Matt Forsyth 9/1/2023
Documents
File Name Date File Size
Lidar 52447 2021-12-08 14.52.42.972.pdf 2025.07.05 93.00kB
Baker Layout 11-9-2021 2021-11-24 12.41.35.178.pdf 2025.07.05 58.56kB
Baker_alteration 2022-11-14 13.17.31.378.pdf 2025.07.05 80.28kB
Site Plan 20220126 103747.pdf 2025.07.05 188.55kB
Subcontractor Form 20220126 103647.pdf 2025.07.05 231.96kB
Roof Inspection Affidavit By Contractor 20220126 103748.pdf 2025.07.05 192.18kB
Termite Certificate_final 20230804 124511.pdf 2025.07.05 204.75kB
Application Information Page 20220126 103547.pdf 2025.07.05 231.95kB
Product Approval Code Specifications Form 20220126 103847.pdf 2025.07.05 235.71kB
Recorded Notice Of Commencement 20220126 103748.pdf 2025.07.05 276.31kB
Blower Door Test Results 20230804 124247.pdf 2025.07.05 316.71kB
Owner And Contractor Signature Page 20220126 103647.pdf 2025.07.05 371.69kB
One Foot Rise 2021-11-22 09.49.35.656.pdf 2025.07.05 123.38kB
Septic Approval Paperwork 20220126 103848.pdf 2025.07.05 445.20kB
Owner Disclosure Statement 20220126 103648.pdf 2025.07.04 749.48kB
Elevation Certificate For Finished Construction 20230804 124248.pdf 2025.07.04 1.21MB
Residential Or Commercial Checklist 20220126 103847.pdf 2025.07.04 1.64MB
43380 Plans.pdf 2025.07.03 9.81MB
Energy Code Forms.pdf 2025.06.22 134.34kB
Elevation Certificate For Finished Construction 20240426 025747.pdf 2025.06.21 1.71MB
Approved Truss Engineering 52447 2021-11-30 10.13.52.378.pdf 2023.12.26 647.43kB
Truss Engineering 2021-11-24 12.41.34.741.pdf 2023.12.26 584.52kB
Certificate Of Occupancy 20230901.pdf 2023.09.01 68.94kB
Power Release-release To Power Company 20230808.pdf 2023.08.08 38.83kB
Original Permit 20211214.pdf 2021.12.14 44.75kB
Manual J Forms.pdf 2021.11.22 29.00kB