Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 190 SW MERIDIAN CT
FORT WHITE, FL 32038
Parcel #: 04255-000
Acres: 0.54
Owner: Drew Worthmann
Subdivision: Hollingsworth Bluff
Zoning: ESA-2
Flood Zone: AE
District: 2
Application #: 52723
Permit #: 000043340
Related Permit:
Submitted: Wednesday, December 8, 2021
Issued: Wednesday, December 8, 2021
Expires: Monday, July 25, 2022
Completed: Monday, July 25, 2022
Status: Completed
Septic Release? na
Notes:
AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 1248
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number fl11671
Product Manufacturer METAL ROOFS DEPOT
Product Description 26 GAUGE METAL PANELS
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0526C
Review Notes
12/2/2021 Application pending.
12/8/2021 Final Review - Documents Required NEEDED: *OWNERS PHONE NUMBER AND EMAIL (IF APPLICABLE) *OWNERS SIGNATURE MUST BE DOUGLAS POWERS OR ANDREA LONG, NOT DREW WORTHMANN *NOC UPLOADED DOES NOT MATH THIS ADDRESS OR OWNER-- PLEASE UPLOAD CORRECT ONE
12/8/2021 Final Review - Payment Needed
12/8/2021 Permit Issued Permit #000043340 created and approved.
Contractors
Name/ Business License Title Role
Michelle Cangialosi
Worthman Llc
County License & State License & Liability Insurance & Workers Comp Expired.
CCC1332820 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 12/21/2021
Failed: Re-Roof - Final Wrong Photos Anthony Aslan 7/21/2022
Passed: Re-Roof - Final Correct Photos Anthony Aslan 7/25/2022