Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 400 SW THORNE LN
FORT WHITE, FL 32038
Parcel #: 10058-636
Acres: 1.50
Owner: Coats, Robert S
Subdivision: Santa Fe River Plantations Replat Of Lots 38,45,46
Zoning: A-3
Flood Zone: X
District: 2
Application #: 52472
Permit #: 000043150
Related Permit:
Submitted: Monday, November 8, 2021
Issued: Friday, November 12, 2021
Expires: Tuesday, November 23, 2021
Completed: Tuesday, November 23, 2021
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) REMOVE EXISTING SHINGLES AND REPLACING WITH NEW SHINGLES.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2310
No. of Stories 1
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Roof Pitch 4:12 or Greater
Any cable and/or race-way wiring located on or within the roof assembly? No
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL5444.1
Product Manufacturer CERTAINTEED
Product Description LANDMMARK ARCH SHINGLES
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Fema map number 12023C0532C
Review Notes
11/8/2021 Application pending.
11/9/2021 Point Review - Processing MICHELLE ROBERT S. COATS SIGNED AS OWNER. PLEASE UPLOAD RECORDED DEED SHOWING HE IS THE OWNER, OTHERWISE, MATTHEW OR ROBIN HOLLINGSOWRTH MUST SIGN.
11/9/2021 Final Review - Documents Required MICHELLE ROBERT S. COATS SIGNED AS OWNER. PLEASE UPLOAD RECORDED DEED SHOWING HE IS THE OWNER, OTHERWISE, MATTHEW OR ROBIN HOLLINGSOWRTH MUST SIGN.
11/10/2021 Final Review - Payment Needed
11/12/2021 Permit Issued Permit #000043150 created and approved.
Contractors
Name/ Business License Title Role
Michelle Cangialosi
Worthman Llc
County License & State License & Liability Insurance & Workers Comp Expired.
CCC1332820 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 11/17/2021
Passed: Re-Roof - Final Anthony Aslan 11/23/2021