Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 437 SE PEACOCK TER
LAKE CITY, FL 32025
Parcel #: 08714-006
Acres: 10.15
Owner: Odum Austin J & Ashley N
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 49804
Permit #: 000043113
Related Permit:
Submitted: Tuesday, July 20, 2021
Issued: Friday, November 5, 2021
Expires: Tuesday, July 5, 2022
Completed: Tuesday, July 5, 2022
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0405C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 2
Heated Area (Sqft) 1806
Total Area (Sqft) 2298
Building Height 22
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0409
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
6/30/2021 Application pending.
7/21/2021 Point Review - Printed-Online Application PLEASE CORRECT THE FOLLOWING: *APPLICANT INFORMATION-- THIS MUST BE EITHER THE CONTRACTOR OR WHOMEVER THE CONTRACTOR HAS AUTHORIZED TO PULL PERMITS ON THEIR BEHALF-- INCLUDE NAME, NUMBER, EMAIL, AND ADDRESS *ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
7/21/2021 Point Review - Reviewed PLEASE CORRECT THE FOLLOWING: *APPLICANT INFORMATION-- THIS MUST BE EITHER THE CONTRACTOR OR WHOMEVER THE CONTRACTOR HAS AUTHORIZED TO PULL PERMITS ON THEIR BEHALF-- INCLUDE NAME, NUMBER, EMAIL, AND ADDRESS *ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058
8/6/2021 Zoning Review - Reviewed PLEASE CORRECT THE FOLLOWING: *APPLICANT INFORMATION-- THIS MUST BE EITHER THE CONTRACTOR OR WHOMEVER THE CONTRACTOR HAS AUTHORIZED TO PULL PERMITS ON THEIR BEHALF-- INCLUDE NAME, NUMBER, EMAIL, AND ADDRESS *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
8/16/2021 Plan Review - Documents Required PLEASE CORRECT THE FOLLOWING: *APPLICANT INFORMATION-- THIS MUST BE EITHER THE CONTRACTOR OR WHOMEVER THE CONTRACTOR HAS AUTHORIZED TO PULL PERMITS ON THEIR BEHALF-- INCLUDE NAME, NUMBER, EMAIL, AND ADDRESS *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. NEED ROOF TRUSS PLANS ONLY HAVE FLOOR TRUSSES
9/2/2021 Plan Review - Plumbing Approved *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/2/2021 Plan Review - Mechanical Approved *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/2/2021 Plan Review - Electrical Approved *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/2/2021 Plan Review - Building Approved *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/2/2021 Plan Review - Reviewed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/10/2021 Zoning Review - Reviewed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/10/2021 Final Review - Reviewed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
9/10/2021 Final Review - Payment Needed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
10/25/2021 Final Review - Payment Needed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
11/5/2021 Permit Issued Permit #000043113 created and approved.
5/11/2022 Final Review - Payment Needed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
5/13/2022 Final Review - Payment Needed *IF MININMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
Contractors
Name/ Business License Title Role
Mark J Mashburn
Americas Home Place Inc
CRC1330787 Residential Contractor Contractor
Nate D Bazinet
Sunshine Plumbing & Gas
County License & State License & Liability Insurance & Workers Comp Expired.
CFC1427687 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 11/22/2021
Cancelled: Building - Footer Anthony Aslan 12/8/2021
Cancelled: Engineering - Setbacks Anthony Aslan 12/8/2021
Passed: Building - Monolithic Slab Need Grounding Wire Anthony Aslan 12/8/2021
Passed: Engineering - Setbacks Anthony Aslan 12/8/2021
Passed: Building - Roof Decking Anthony Aslan 1/12/2022
Passed: Building - Wall Sheathing Need Safety Railing On Stairs And Loft Anthony Aslan 1/12/2022
Passed: Electrical - 2nd Rough-In Anthony Aslan 3/1/2022
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 3/1/2022
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 3/1/2022
Failed: Building - Framing Bearing Walls Notch Or Cut More Than 50% Require Cts218 Tension Strap, r602.6drilling And Notching Of Studs. r602.6.1drilling And Notching Of Top Plate. Anthony Aslan 3/1/2022
Failed: Mechanical - Rough In Supplies And Returns No Tape On Tap Collar Or Internal Flex Joint, Duct Splices Have No Splicing Collar, Downstairs Return Restricted, Unit Located In Attic Does Not Have Access For Removal. Downstairs Hall Bath Exhaust Fan Pulled Down. m1305.1.3appliances In Attics. Anthony Aslan 3/1/2022
Cancelled: Plumbing/Gas - 2nd Rough-In Janice Williams 3/16/2022
Failed: Building - Framing No Correction Made, Do Not Sheet Rock Anthony Aslan 3/17/2022
Failed: Mechanical - Rough In -sealing Of Duct Collars Has Not Been Addressed -m1601.4.1joints, Seams And Connections. -opening Is 24"x 24" m1305.1.3appliances In Attics. 20"x30"min Opening. Anthony Aslan 3/17/2022
Passed: Mechanical - Rough In Anthony Aslan 3/22/2022
Passed: Building - Framing Anthony Aslan 3/22/2022
Passed: Building - Insulation Anthony Aslan 3/22/2022
Septic Release Inspection Health Dept 4/4/2022
Passed: Electrical - Permanent Power Floor Outlets Safety Off, Need Eta On Window Tape And Siding Completion. Anthony Aslan 5/12/2022
Cancelled: Electrical - Permanent Power Emaleigh Williams 5/13/2022
Failed: Electrical - Permanent Power Floor Outlets Not Safety Off, Need Eta On Window Tape And Siding Completion. Anthony Aslan 5/16/2022
Passed: Electrical - Permanent Power Anthony Aslan 6/7/2022
Release to power company Anthony Aslan 6/7/2022
Failed: Building - Final Appliances Not Installed And Wires Not Safety Off, Sinks Leak Under Cabinets, Blower Door Test, Gfci On Back Of House Next To Water Heater Not Working, Kitchen Exhaust Not Complete Anthony Aslan 6/28/2022
Passed: Building - Final Corrections Made Anthony Aslan 7/5/2022
Documents
File Name Date File Size
Power Release-electrical-permanent Power 20220607.pdf 2025.07.05 11.49kB
Original Permit 20211105.pdf 2025.07.05 29.10kB
Lidar 49804 2021-08-06 11.14.10.956.pdf 2025.07.05 145.75kB
Termite Certificate_final 20220705 114347.pdf 2025.07.05 128.96kB
Termite Treatment_initial 20211208 120547.pdf 2025.07.05 134.32kB
Blower Door Test Results 20220705 114348.pdf 2025.07.05 237.90kB
Structural Analysis Report 20211208 120647.pdf 2025.07.05 214.25kB
Bnz Invoice 2021-09-10.pdf 2025.07.05 184.23kB
Site Plan 20210630 152911.pdf 2025.07.05 169.62kB
Manual J Forms 20210630 152909.pdf 2025.07.05 192.22kB
Subcontractor Form 20211104 103123.pdf 2025.07.05 193.81kB
Product Approval Code Specifications Form 20210630 155812.pdf 2025.07.05 198.36kB
Property Appraiser Parcel Details Printed Page 20210630 152909.pdf 2025.07.04 282.70kB
Architectural Plans 20210902 094639.pdf 2025.07.04 350.46kB
Owner And Contractor Signature Page 20210701 123527.pdf 2025.07.04 378.09kB
Approved Rafter Plans 49804 2021-09-02 13.52.53.720.pdf 2025.07.04 396.86kB
Architectural Plans 20210713 114712.pdf 2025.07.04 1.39MB
Septic Approval Paperwork 20210630 152910.pdf 2025.07.04 1.13MB
Residential Or Commercial Checklist 20210630 155812.pdf 2025.07.04 1.37MB
Structural Engineering And Wind Load Calculations 20210630 152911.pdf 2025.07.04 3.06MB
Approved Structural Windload 49804 2021-08-16 08.22.12.569.pdf 2025.07.04 3.13MB
Energy Code Forms 20210630 152907.pdf 2025.07.04 3.25MB
Truss Engineering 20210630 152913.pdf 2025.07.04 4.26MB
Approved Truss Plans For Floor 49804 2021-08-16 08.12.13.455.pdf 2025.07.04 4.29MB
Plumbing Subcontractor Form.pdf 2025.06.22 197.90kB
Mechanical Sub Vf.pdf 2025.06.21 426.24kB
Recorded Deed 20210630 143612.pdf 2023.12.23 81.75kB
Certificate Of Occupancy 20220705.pdf 2023.12.23 62.18kB
Recorded Notice Of Commencement 20211105 083445.pdf 2023.12.23 75.94kB
911 Address Form 20210712 125506.pdf 2023.12.23 82.61kB