Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 250 SW CAMPHOR CT
LAKE CITY, FL 32024
Parcel #: 02732-308
Acres: 1.40
Owner: Anderson Joseph And Wilma J
Subdivision: Laurel Lake Phase 3 (portion Of Lot 7)
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 50322
Permit #: 000043100
Related Permit: Culvert Waiver: 000043101
Submitted: Tuesday, October 19, 2021
Issued: Thursday, November 4, 2021
Expires: Thursday, September 28, 2023
Completed: Thursday, September 28, 2023
Status: Completed
Septic Release? Yes
Notes:
PER SITE PLAN, HOME BEING PLACED TO CLOSE TO LOT 8 SETBACKS, THEREFORE LOTS 7 & 8 MUST REMAIN IN COMMON OWNERSHIP. SEE ATTACHED SETBACK REGULATION PAGE FOR RULES. NO UTILITY EASEMENTS BETWEEN THESE LOTS. ELEVATION CONFIRMATION REC'D @ 131.2'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2125
Total Area (Sqft) 3013
Stories 1
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Septic# (00-0000) or (X00-000) x-city
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Subdivision Plat
Finished floor requirement 114.0' & 1' ABOVE HIGHEST ADJACENT GRADE AT BUILD SITE One foot above the road
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Review Notes
8/22/2021 Application pending.
10/21/2021 Point Review - Printed-Online Application NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/21/2021 Point Review - Reviewed NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/25/2021 Plan Review - Building Approved NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/25/2021 Plan Review - Electrical Approved NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/25/2021 Plan Review - Mechanical Approved NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/25/2021 Plan Review - Plumbing Approved NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/25/2021 Plan Review - Reviewed NEEDED: *MORE DETAILED SITE PLAN WITH DIMENSIONS TO THE PROPOSED LOCATION OF HOME
10/28/2021 Zoning Review - Reviewed
11/1/2021 Zoning Review - Reviewed
11/4/2021 Permit Issued Permit #000043100 created and approved.
5/10/2023 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
John Harrington Jr
House Craft Homes Residential & Commercial Llc (dba Name)
Liability Insurance Expired.
CGC1525983 General Contractor Contractor
Roger Whiddon
Lake City Plumbing Inc
CFC1428686 Cert Plumbing Subcontractor
Brennon Battles
Beast Electric Llc
County License & State License & Liability Insurance & Workers Comp Expired.
EC13007878 Cert. Electrical Subcontractor
Raymond Walsh
Florida Home Perfomance Dba North Central Florida Air Conditioning
County License & State License & Liability Insurance & Workers Comp Expired.
CMC1250824 Cert. Mechanical Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 11/30/2021
Passed: Engineering - Setbacks Matt Forsyth 11/30/2021
Passed: Electrical - Temporary Service Matt Forsyth 1/19/2022
Release to power company Matt Forsyth 1/19/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 1/19/2022
Passed: Building - Slab Bate System Will Be Used For Termite Treatment Also Need Proof Of Fiber Mesh Concrete Being Used Leave Concrete Tickets In Permit Box Matt Forsyth 1/26/2022
Passed: Building - Masonry Wall Reinforcing Matt Forsyth 3/7/2022
Passed: Electrical - Temporary Service Matt Forsyth 3/10/2022
Release to power company Matt Forsyth 3/10/2022
Failed: Building - Slab Need Elevation Confirmation Letter Prior To Anymore Inspections Troy Crews 6/10/2022
Passed: Building - Roof Decking Matt Forsyth 8/31/2022
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 8/31/2022
Passed: Mechanical - Rough In Exaustfan Duct Extended To Outside Matt Forsyth 10/12/2022
Failed: Building - Insulation No Insulation Inspection Until All Second Roughs Are Complete Matt Forsyth 10/24/2022
Passed: Building - Framing Matt Forsyth 11/4/2022
Failed: Electrical - 2nd Rough-In Receptacles Along The Wall Not Cut In Properly Matt Forsyth 11/4/2022
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 11/4/2022
Passed: Mechanical - Rough In Bath Fan Ducks Have Been Exhausted To The Outside Troy Crews 11/21/2022
Passed: Electrical - 2nd Rough-In Boxes Installed Troy Crews 11/21/2022
Failed: Building - Insulation Need To Repair Insulation In Garage And Call Back In Troy Crews 11/21/2022
Passed: Building - Insulation Matt Forsyth 11/30/2022
Failed: Electrical - Permanent Power Need Pipe Ran For Service Entrance Conductors Matt Forsyth 5/11/2023
Passed: Electrical - Permanent Power Matt Forsyth 6/9/2023
Release to power company Matt Forsyth 6/9/2023
Passed: Building - Final Matt Forsyth 9/28/2023
Documents
File Name Date File Size
Laurel_lake_phs3 Lots 7-8 2021-11-01 14.37.08.824 (1) 2021-11-08 17.29.55.409.pdf 2023.12.24 960.74kB
Property Appraiser Parcel Details Printed Page 20210827 174027.pdf 2023.12.24 636.85kB
Power Release-electrical-temporary Service 20220310.pdf 2023.12.24 38.99kB
250 Sw Camphor Ct 2021-09-13 12.23.18.941.pdf 2023.12.24 245.82kB
Truss Engineering 20210928 110211.pdf 2023.12.24 2.15MB
Subcontractor Form 20211001 162118.pdf 2023.12.24 1.81MB
Win_20230928_10_45_59_pro 2023-09-28 10.46.55.310.jpg 2023.12.24 261.95kB
Energy Code Forms 20210827 174025.pdf 2023.12.24 2.46MB
Recorded Notice Of Commencement 20211003 163829.pdf 2023.12.24 105.17kB
Certificate Of Occupancy 20230928.pdf 2023.12.24 69.23kB
Owner And Contractor Signature Page 20211007 152832.pdf 2023.12.24 762.26kB
Win_20220119_11_46_51_pro 2022-01-19 11.47.24.626.jpg 2023.12.24 191.00kB
Lidar 50322 2021-10-28 14.18.40.159.pdf 2023.12.24 80.65kB
Power Release-electrical-temporary Service 20220119.pdf 2023.12.24 38.86kB
Approved Truss Engineering 50322 2021-10-25 09.35.35.600.pdf 2023.12.24 2.28MB
Approved Architectural Plans 50322 2021-10-25 09.35.03.662.pdf 2023.12.24 5.20MB
Architectural Plans 20211017 170756.pdf 2023.12.24 3.92MB
Surveyor Letter Giving The Finished Floor Elevation 20220612 131917.pdf 2023.12.24 36.23kB
City Or County Utility Availability Letter 20211019 063247.pdf 2023.12.24 249.28kB
Win_20230928_10_46_20_pro 2023-09-28 10.47.07.684.jpg 2023.12.24 114.74kB
Manual J Forms 20210827 174027.pdf 2023.12.24 18.61kB
Original Permit 20211104.pdf 2023.12.24 44.80kB
Site Plan 20211023 162028.pdf 2023.12.24 308.22kB
Product Approval Code Specifications Form 20211001 162117.pdf 2023.12.24 509.50kB
Residential Or Commercial Checklist.pdf 2023.12.24 1.08MB
Recorded Deed 20210827 171619.pdf 2023.12.24 1.55MB
Power Release-electrical-permanent Power 20230609.pdf 2023.12.24 39.11kB