Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 166 SW FEATHER LN
FORT WHITE, FL 32038
Parcel #: 04321-053
Acres: 9.19
Owner: Newton Roger W
Subdivision: Rum Island Ranches Unr
Zoning: A-3
Flood Zone: X
District: 2
Application #: 52130
Permit #: 000043064
Related Permit:
Submitted: Thursday, October 14, 2021
Issued: Thursday, October 28, 2021
Expires: Wednesday, May 11, 2022
Completed: Wednesday, May 11, 2022
Status: Completed
Septic Release? Yes
Notes:

Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1833
Total Area (Sqft) 1906
Stories 1
Building Height 10
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30'
Setback Side 1 2ND FRONT - 30'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 21-0843
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0531C
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) a self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof.
Review Notes
10/14/2021 Application pending.
10/15/2021 Point Review - On Hold-Incomplete KAREN: PLEASE ONLY SHARE AN EMAIL FOR THE OWNER IF ONE IS AVAILABLE. ALSO, PLEASE FILL IN ENGINEER/ARCHITECT CELL AS REQUESTED. NEEDED: PRODUCT APPROVAL SHEET ENVIRONMENTAL HEALTH PAPERWORK - 386.758.1058
10/21/2021 Point Review - Printed-Online Application NEEDED: MARIO - CURRENT CERT. OF LIABILITY ENVIRONMENTAL HEALTH PAPERWORK - 386.758.1058
10/26/2021 Plan Review - Plumbing Approved NEEDED: MARIO - CURRENT CERT. OF LIABILITY
10/26/2021 Plan Review - Mechanical Approved NEEDED: MARIO - CURRENT CERT. OF LIABILITY
10/26/2021 Plan Review - Electrical Approved NEEDED: MARIO - CURRENT CERT. OF LIABILITY
10/26/2021 Plan Review - Building Approved NEEDED: MARIO - CURRENT CERT. OF LIABILITY
10/26/2021 Plan Review - Reviewed NEEDED: MARIO - CURRENT CERT. OF LIABILITY
10/27/2021 Zoning Review - Reviewed NEEDED: MARIO - CURRENT CERT. OF LIABILITY DEES - CURRENT WORKERS COMP CERTIFICATE
10/27/2021 Final Review - Documents Required NEEDED: MARIO - CURRENT CERT. OF LIABILITY DEES - CURRENT WORKERS COMP CERTIFICATE
10/28/2021 Final Review - Payment Needed
10/28/2021 Permit Issued Permit #000043064 created and approved.
3/16/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Richard A Hunt
Todays Heating & Air Inc
CAC012076 Cert. A/c Class “a” Subcontractor
George W Grimm
George Grimm Electric, Inc.
EC13007091 Cert. Electrical Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Mario M Spadavecchia
A & M Plumbing Enterprises Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CFC1426551 Cert. Plumbing Subcontractor
Patricia S Dees
Steve Smith Construction, Inc.
County License & State License & Liability Insurance & Workers Comp Expired.
CBC1256817 Cert. Building Contractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 11/2/2021
Passed: Electrical - Temporary Service Anthony Aslan 11/8/2021
Release to power company Anthony Aslan 11/8/2021
Passed: Engineering - Setbacks Anthony Aslan 11/8/2021
Passed: Building - Monolithic Slab Anthony Aslan 11/8/2021
Passed: Building - Lintel/Tie Beam Anthony Aslan 11/19/2021
Passed: Building - Lintel/Tie Beam Did Not Find Paperwork In Permit Box Summit To Office Anthony Aslan 12/3/2021
Passed: Building - Roof Decking Anthony Aslan 12/15/2021
Failed: Mechanical - Rough In No Screws In Kitchen Exhaust Pipe Joints, Fire Place Not Vented Anthony Aslan 1/3/2022
Failed: Plumbing/Gas - 2nd Rough-In Nail Guards Missing Marked With Red Marker Anthony Aslan 1/3/2022
Failed: Building - Framing T05 Truss On Right Side Of Missing Engineering, No Windows Installed. Need Windows Before Insulation Anthony Aslan 1/3/2022
Failed: Electrical - 2nd Rough-In Smoke Detectors Must Not Be Closer Than 3'ft From Supplies Or Returns Anthony Aslan 1/3/2022
Passed: Electrical - 2nd Rough-In Anthony Aslan 1/7/2022
Passed: Mechanical - Rough In Anthony Aslan 1/7/2022
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 1/7/2022
Passed: Building - Framing Don't Insulate Before Windows Are Installed! Anthony Aslan 1/7/2022
Passed: Building - Insulation Cover Broken Window Anthony Aslan 2/3/2022
Cancelled: Building - Final Anthony Aslan 4/19/2022
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 4/19/2022
Septic Release Inspection Health Dept 5/2/2022
Release to power company Melissa Garber 5/3/2022
Passed: Building - Final Need Blower Door Test, Master Window? Anthony Aslan 5/10/2022
Certificate-Release Certificate Per Conversation With Home Owner On 5-11-22 1:43pm, Okay With Master Window To Be Repaired. Anthony Aslan 5/11/2022
Documents
File Name Date File Size
Site Plan 20211014 150056.pdf 2023.12.26 461.78kB
Truss Engineering 20211014 150100.pdf 2023.12.26 12.48MB
Owner Disclosure Statement 20211014 150054.pdf 2023.12.26 724.33kB
Residential Or Commercial Checklist 20211014 150055.pdf 2023.12.26 3.09MB
Lidar Map 52130 2021-10-27 10.46.39.190.pdf 2023.12.26 141.83kB
Recorded Notice Of Commencement 20211020 143912.pdf 2023.12.26 58.42kB
Approved Structural 52130 2021-10-26 07.53.20.396.pdf 2023.12.26 6.42MB
Energy Code Forms 20211014 150051.pdf 2023.12.26 3.61MB
Architectural Plans 20211014 150049.pdf 2023.12.26 6.35MB
43064 Final Spray 2022-05-10 15.10.23.680.jpg 2023.12.26 82.32kB
Recorded Notice Of Commencement 20211029 103527.pdf 2023.12.26 58.42kB
Termite Certificate_final 20220511 081547.pdf 2023.12.26 189.76kB
Property Appraiser Parcel Details Printed Page 20211014 150054.pdf 2023.12.26 724.33kB
Subcontractor Form 20211014 150059.pdf 2023.12.26 533.00kB
Certificate Of Occupancy 20220511.pdf 2023.12.26 62.17kB
Manual J Forms 20211014 150053.pdf 2023.12.26 3.61MB
Owner And Contractor Signature Page 20211014 143105.pdf 2023.12.26 814.16kB
Power Release-electrical-temporary Service 20211108.pdf 2023.12.26 38.88kB
Approved Truss Plans 52130 2021-10-26 07.50.06.681.pdf 2023.12.26 12.53MB
Power Release-release To Power Company 20220503.pdf 2023.12.26 39.02kB
Structural Engineering And Wind Load Calculations 20211014 150056.pdf 2023.12.26 12.48MB
Original Permit 20211028.pdf 2023.12.26 42.89kB
Product Approval Code Specifications Form 20211020 143911.pdf 2023.12.26 201.45kB
Blower Door Test.pdf 2023.12.26 154.26kB
Septic Approval Paperwork 20211020 143912.pdf 2023.12.26 1.45MB
Termite Treatment_initial 20211109 082146.pdf 2023.12.26 197.93kB
Contractor Letter Of Authorization 20211014 150051.pdf 2023.12.26 524.50kB
Structural Analysis Report 20211109 082049.pdf 2023.12.26 341.88kB
Recorded Deed 20211014 143106.pdf 2023.12.26 56.45kB