Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 199 SW CHERRYWOOD WAY
LAKE CITY, FL 32025
Parcel #: 09415-102
Acres: 5.01
Owner: Lawrence Jonathan S & Erica
Subdivision: Magnolia Place
Zoning: A-3
Flood Zone: A
District: 4
Application #: 51698
Permit #: 000043008
Related Permit: Culvert Waiver: 000043009
Submitted: Wednesday, September 22, 2021
Issued: Friday, October 22, 2021
Expires: Wednesday, August 10, 2022
Completed: Wednesday, August 10, 2022
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D AT 125.95'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2407
Total Area (Sqft) 3605
Stories 1
Building Height 24
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 21-0829
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Subdivision Plat
Finished floor requirement HIGHER OF: ELEVATION 120' OR 1' ABOVE THE ROADWAY OR 8" ABOVE HIGHEST ADJACENT GRADE
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0415C
In floodway N
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
9/22/2021 Application pending.
9/23/2021 Point Review - Printed-Online Application NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/23/2021 Point Review - Reviewed NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/27/2021 Zoning Review - Reviewed NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/30/2021 Plan Review - Building Approved NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/30/2021 Plan Review - Electrical Approved NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/30/2021 Plan Review - Mechanical Approved NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/30/2021 Plan Review - Plumbing Approved NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
9/30/2021 Plan Review - Reviewed NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
10/7/2021 Zoning Review - Reviewed NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
10/7/2021 Final Review - Documents Required MATT: AWAITS CORRECTIONS!! NEEDED: *OWNER PHONE # & EMAIL-- NOT CONTRACTORS *SELECT ROOF OPTION *PLEASE ADD ARCHITECT INFORMATION TO UNDER APPLICANT DETAILS *RESIDENTIAL CHECKLIST-- DOES NOT MATCH SQUARE FOOTAGE SUBMITTED *ENV HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-1058 ***PRIOR TO INSPECTIONS*** RECORDED NOC
10/22/2021 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
10/22/2021 Permit Issued Permit #000043008 created and approved.
6/15/2022 Final Review - Payment Needed ***PRIOR TO INSPECTIONS*** RECORDED NOC
Contractors
Name/ Business License Title Role
Matthew Hentzelman
Trademark Construction Group Inc.
County License & State License Expired.
CGC1514780 General Contractor Contractor
Matthew Hentzelman
Trademark Construction Group, Inc.
County License & State License Expired.
CCC1329208 Roofing Contractor Subcontractor
David P Wood
Wood's Electrical Services Inc
Liability Insurance & Workers Comp & Employees Workers Comp Expired.
EC13002213 Electrical Contractor Subcontractor
David E Hall
David Hall's Air Cond & Heating Svc,inc.
Liability Insurance Expired.
CAC057424 Class B A/c Contractor Subcontractor
Roger Whiddon
Lake City Plumbing Inc
CFC1428686 Cert Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Setbacks Anthony Aslan 12/6/2021
Passed: Building - Footer Anthony Aslan 12/6/2021
Passed: Electrical - Temporary Service Anthony Aslan 12/17/2021
Release to power company Anthony Aslan 12/17/2021
Cancelled: Electrical - 1st Underground Rough–In Janice Williams 1/4/2022
Cancelled: Electrical - 1st Underground Rough–In Janice Williams 1/4/2022
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 1/5/2022
Passed: Building - Slab Troy Crews 1/18/2022
Failed: Building - Roof Decking Not Completed Anthony Aslan 3/9/2022
Cancelled: Building - Roof Decking Melissa Garber 3/11/2022
Passed: Building - Roof Decking Anthony Aslan 3/15/2022
Passed: Building - Strapping Anthony Aslan 3/21/2022
Passed: Building - Wall Sheathing Anthony Aslan 3/21/2022
Cancelled: Building - Strapping Anthony Aslan 3/22/2022
Cancelled: Building - Wall Sheathing Anthony Aslan 3/22/2022
Failed: Building - Framing Missing Threaded Rod Front Door, Back Porch Window, Anthony Aslan 4/12/2022
Failed: Mechanical - Rough In No Screws In Kitchen Exhaust Joints, Dryer Pipe Running Wrong Direction & Not Sealed Through Roof, Exhaust Fans Not Strapped, Flex Missing Straps, Gasket Missing On A Return And A Supply, Connections Sealed From Outside Can Not Verify Internal Sealing. Need Nail Guard Dryer Pipe Anthony Aslan 4/12/2022
Failed: Plumbing/Gas - 2nd Rough-In Nail Guards Missing Master Shower Supply Anthony Aslan 4/12/2022
Passed: Electrical - 2nd Rough-In Metal Box No Ground Screw To Box Anthony Aslan 4/12/2022
Cancelled: Electrical - 2nd Rough-In Anthony Aslan 4/18/2022
Passed: Building - Framing Anthony Aslan 4/18/2022
Passed: Mechanical - Rough In Anthony Aslan 4/18/2022
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 4/18/2022
Passed: Building - Insulation Walls Only Anthony Aslan 4/18/2022
Passed: Building - Insulation Spray Foam Attic Anthony Aslan 4/25/2022
Septic Release Inspection Health Dept 6/13/2022
Release to power company Rec'd Pictures Anthony Aslan 6/16/2022
Passed: Electrical - Permanent Power Need Pictures Of Outside Outlets With Covers, Bathroom Vanities Safe Off Wires. Anthony Aslan 6/16/2022
Failed: Building - Final No Anchors On Condenser, No Locking Caps On Service Ports, Less Than 3'ft From Main Service Panel And In Front Of A/c Disconnect. air Handler Plenum At Unit Connection Not Properly Sealed, Return Under Unit Not Properly Sealed. outlets Under Eves, Porch No Outlet Protection Covers. Anthony Aslan 8/8/2022
Passed: Building - Final Correction Made Anthony Aslan 8/10/2022
Documents
File Name Date File Size
Approved Truss Engineering 51698 2021-09-30 13.24.47.47.pdf 2023.12.26 2.70MB
Structural Engineering And Wind Load Calculations 20210922 140544.pdf 2023.12.26 825.01kB
Blower Door Test Results 20220809 083301.pdf 2023.12.26 403.64kB
Original Permit 20211022.pdf 2023.12.26 44.66kB
Architectural Plans 20211007 105439.pdf 2023.12.26 1.68MB
Approved Architectural Plans 51698 2021-09-30 13.35.24.656.pdf 2023.12.26 4.85MB
Engineer Letter.pdf 2023.12.26 3.53MB
Owner And Contractor Signature Page 20210922 130742.pdf 2023.12.26 109.35kB
911 Address Form 20210922 144359.pdf 2023.12.26 1.73MB
Lidar 51698 2021-09-27 11.33.41.614.pdf 2023.12.26 82.14kB
Recorded Deed 20210922 140258.pdf 2023.12.26 92.45kB
Power Release-release To Power Company 20220616.pdf 2023.12.26 39.01kB
Win_20220118_16_23_20_pro 2022-01-18 16.52.20.657.jpg 2023.12.26 124.77kB
Property Appraiser Details.pdf 2023.12.26 413.99kB
Residential Or Commercial Checklist 20211007 130748.pdf 2023.12.26 1.04MB
Power Release-electrical-temporary Service 20211217.pdf 2023.12.26 38.88kB
Certificate Of Occupancy 20220810.pdf 2023.12.26 62.24kB
Revised A1 To Correct Code 2021-10-08 09.27.09.33.pdf 2023.12.26 1.68MB
Approved Structural Engineering And Wind Load Calculations 51698 2021-09-30 13.36.44.128.pdf 2023.12.26 864.22kB
Surveyor Letter Giving The Finished Floor Elevation 2021-12-17 13.15.47.360.pdf 2023.12.26 40.76kB
Subcontractor Form 20210922 135848.pdf 2023.12.26 66.93kB
Manual J Forms 20210922 135847.pdf 2023.12.26 64.13kB
Product Approval Code Specifications Form 20210922 135847.pdf 2023.12.26 211.86kB
Architectural Plans 20210922 140543.pdf 2023.12.26 4.79MB
Property Appraiser Parcel Details Printed Page 20210922 140258.pdf 2023.12.26 416.08kB
Final Termite 43008 2022-08-09 11.34.39.809.jpg 2023.12.26 72.06kB
Septic Approval Paperwork 20211022 092312.pdf 2023.12.26 921.13kB
Energy Code Forms 20210922 135847.pdf 2023.12.26 396.00kB
Truss Engineering 20210922 135849.pdf 2023.12.26 2.59MB
Recorded Notice Of Commencement 20211203 095054.pdf 2023.12.26 131.28kB
Site Plan 20210922 160254.pdf 2023.12.26 74.79kB