Inspection |
Notes |
Performed By |
Date |
Passed: Engineering - Setbacks |
|
Anthony Aslan |
12/6/2021 |
Passed: Building - Footer |
|
Anthony Aslan |
12/6/2021 |
Passed: Electrical - Temporary Service |
|
Anthony Aslan |
12/17/2021 |
Release to power company |
|
Anthony Aslan |
12/17/2021 |
Cancelled: Electrical - 1st Underground Rough–In |
|
Janice Williams |
1/4/2022 |
Cancelled: Electrical - 1st Underground Rough–In |
|
Janice Williams |
1/4/2022 |
Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Anthony Aslan |
1/5/2022 |
Passed: Building - Slab |
|
Troy Crews |
1/18/2022 |
Failed: Building - Roof Decking |
Not Completed |
Anthony Aslan |
3/9/2022 |
Cancelled: Building - Roof Decking |
|
Melissa Garber |
3/11/2022 |
Passed: Building - Roof Decking |
|
Anthony Aslan |
3/15/2022 |
Passed: Building - Strapping |
|
Anthony Aslan |
3/21/2022 |
Passed: Building - Wall Sheathing |
|
Anthony Aslan |
3/21/2022 |
Cancelled: Building - Strapping |
|
Anthony Aslan |
3/22/2022 |
Cancelled: Building - Wall Sheathing |
|
Anthony Aslan |
3/22/2022 |
Failed: Building - Framing |
Missing Threaded Rod Front Door, Back Porch Window, |
Anthony Aslan |
4/12/2022 |
Failed: Mechanical - Rough In |
No Screws In Kitchen Exhaust Joints, Dryer Pipe Running Wrong Direction & Not Sealed Through Roof, Exhaust Fans Not Strapped, Flex Missing Straps, Gasket Missing On A Return And A Supply, Connections Sealed From Outside Can Not Verify Internal Sealing. Need Nail Guard Dryer Pipe |
Anthony Aslan |
4/12/2022 |
Failed: Plumbing/Gas - 2nd Rough-In |
Nail Guards Missing Master Shower Supply |
Anthony Aslan |
4/12/2022 |
Passed: Electrical - 2nd Rough-In |
Metal Box No Ground Screw To Box |
Anthony Aslan |
4/12/2022 |
Cancelled: Electrical - 2nd Rough-In |
|
Anthony Aslan |
4/18/2022 |
Passed: Building - Framing |
|
Anthony Aslan |
4/18/2022 |
Passed: Mechanical - Rough In |
|
Anthony Aslan |
4/18/2022 |
Passed: Plumbing/Gas - 2nd Rough-In |
|
Anthony Aslan |
4/18/2022 |
Passed: Building - Insulation |
Walls Only |
Anthony Aslan |
4/18/2022 |
Passed: Building - Insulation |
Spray Foam Attic |
Anthony Aslan |
4/25/2022 |
Septic Release Inspection |
|
Health Dept |
6/13/2022 |
Release to power company |
Rec'd Pictures |
Anthony Aslan |
6/16/2022 |
Passed: Electrical - Permanent Power |
Need Pictures Of Outside Outlets With Covers, Bathroom Vanities Safe Off Wires. |
Anthony Aslan |
6/16/2022 |
Failed: Building - Final |
No Anchors On Condenser, No Locking Caps On Service Ports, Less Than 3'ft From Main Service Panel And In Front Of A/c Disconnect.
air Handler Plenum At Unit Connection Not Properly Sealed, Return Under Unit Not Properly Sealed.
outlets Under Eves, Porch No Outlet Protection Covers. |
Anthony Aslan |
8/8/2022 |
Passed: Building - Final |
Correction Made |
Anthony Aslan |
8/10/2022 |