Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit

Address 108 SW BALLARD CT
LAKE CITY, FL 32024
Parcel #: 00358-004
Acres: 10.00
Owner: Bkl Investment Co (timothy & Michelle Ballard-mh)
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 50446
Permit #: 000042965
Related Permit:
Submitted: Thursday, September 2, 2021
Issued: Friday, October 15, 2021
Expires: Wednesday, December 15, 2021
Completed: Wednesday, December 15, 2021
Status: Completed
Septic Release? Yes
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0294D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 0.00
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL35321
Product Manufacturer Tamko
Product Description Rustic Black
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Off-ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
9/2/2021 Application pending.
9/2/2021 Point Review - Printed-Online Application
9/2/2021 Point Review - Reviewed
9/20/2021 Plan Review - Reviewed
9/29/2021 Zoning Review - Reviewed
9/30/2021 Final Review - Reviewed
10/15/2021 Final Review - Payment Needed
10/15/2021 Permit Issued
Contractors
Name/ Business License Title Role
Ernest S Johnson
Dependable Mobile Home Service
IH1025249 Mh Installer (ih) Contractor
James D Williams
Affordable Electrical Services Inc
Workers Comp Expired.
EC13007092 Electrical Contractor Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 10/15/2021
Passed: Mobile Home - Mobile Home Set-Up Final Matt Forsyth 12/15/2021
Release to power company Matt Forsyth 12/15/2021
Passed: Engineering - Setbacks Matt Forsyth 12/15/2021
Documents
File Name Date File Size