Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 337 SW BLUE JAY CT
FORT WHITE, FL 32038
Parcel #: 04060-101
Acres: 1.53
Owner: Trowbridge Cynthia Kay
Subdivision: Fort White Park
Zoning:
Flood Zone: X
District: 2
Application #: 52001
Permit #: 000042926
Related Permit:
Submitted: Thursday, October 21, 2021
Issued: Friday, October 8, 2021
Expires: Wednesday, April 6, 2022
Completed:
Status: Permit Issued
Septic Release? na
Notes:
AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0490C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 40
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL35321
Product Manufacturer tamko
Product Description Non-ASTM D3462 asphalt roof shingles and ridge cap shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Review Notes
10/6/2021 Final Review - Corrections Needed NEEDED: *OWNERS PHONE NUMBER *ROOF OPTION SELECTED
10/8/2021 Permit Issued Permit #000042926 created and approved.
Contractors
Name/ Business License Title Role
David J Pabst
Whittle Roofing Company, Inc.
CCC1326372 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date