Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Storage Building Permit

Address 359 SE SEAWOLF WAY
HIGH SPRINGS, FL 32643
Parcel #: 09860-002
Acres: 2.03
Owner: Collar John & Sharon
Subdivision: Hawks Ridge Acres
Zoning: A-3
Flood Zone: X
District: 4
Application #: 50411
Permit #: 000042808
Related Permit:
Submitted: Friday, October 22, 2021
Issued: Wednesday, September 22, 2021
Expires: Tuesday, January 4, 2022
Completed: Tuesday, January 4, 2022
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Accessory Use
Finished floor requirement Non-Habitable Structure
Fema map number 12023C0512C
In floodway N
Type of Structure Storage Building
Commercial or Residential? Residential
Total Area (Sqft) 2700
Septic# (00-0000) or (X00-000) 21-0714
Setbacks Front 51'
Setback Side 1 50'
Setback Side 2 65'
Setback Rear 349'
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Storage
Occupancy Use Title storage building
Dev Permit # F023-
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Building Height 11'9"
Length 90'
Width 30'
Review Notes
8/30/2021 Point Review - Received-Hard Copy Application
8/30/2021 Point Review - Reviewed
9/9/2021 Zoning Review - Reviewed
9/13/2021 Plan Review - Building Approved
9/13/2021 Plan Review - Reviewed
9/22/2021 Permit Issued Permit #000042808 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 8/31/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Need Compaction Test On Pad More Than 12" Of Fill Dirt Anthony Aslan 10/21/2021
Passed: Engineering - Setbacks Anthony Aslan 10/26/2021
Passed: Building - Footer Did Not See Grounding Wire Anthony Aslan 10/26/2021
Passed: Building - Final Anthony Aslan 1/4/2022
Release to power company Melissa Garber 2/28/2022