Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 198 SW GRASSY LN
FT. WHITE, FL 32038
Parcel #: 03814-101
Acres: 10.01
Owner: Stephan Gregory A
Subdivision: Southfork Unr
Zoning: A-3
Flood Zone: X
District: 4
Application #: 50430
Permit #: 000042801
Related Permit:
Submitted: Wednesday, September 1, 2021
Issued: Wednesday, September 22, 2021
Expires: Wednesday, May 18, 2022
Completed: Wednesday, May 18, 2022
Status: Completed
Septic Release? Yes
Notes:

Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1850
Total Area (Sqft) 2657
Stories 1
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 21-0736
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0480C
In floodway N
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
8/31/2021 Application pending.
9/1/2021 Point Review - On Hold-Incomplete STAFF: PLEASE UPLOAd ALL NECESSARY DOCUMENTS!
9/1/2021 Point Review - Printed-Online Application LESLIE: DRIVEWAY ACCESS OFF 47-S -CONTACT FDOT OR IF ITS COMING OFF PRIVATE, COUNTY HAS NO JURISDICTION.
9/20/2021 Plan Review - Documents Required NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS E-MAIL DIGITAL SEAL COPY FOR FILE
9/20/2021 Zoning Review - Reviewed NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS E-MAIL DIGITAL SEAL COPY FOR FILE
9/21/2021 Plan Review - Plumbing Approved NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS
9/21/2021 Plan Review - Mechanical Approved NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS
9/21/2021 Plan Review - Electrical Approved NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS
9/21/2021 Plan Review - Building Approved NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS
9/21/2021 Plan Review - Reviewed NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS
9/21/2021 Final Review - Documents Required NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS
9/21/2021 Final Review - Documents Required NEEDED: ENVIRONMENTAL HEALTH APPROVED PAPERWORK - 386.758.1058 911 ADRESS - I N EED THE ADDRESS SHEET, NOT 911 REQUEST FORM
9/22/2021 Final Review - Payment Needed
9/22/2021 Permit Issued Permit #000042801 created and approved.
4/6/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Leslie R Mcdaniel
Reed Mcdaniel Construction Inc
CBC1255787 Cert. Building Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Richard M Touchstone
Touchstone Heating & Air Inc
CAC058099 Class B A/c Contractor Subcontractor
Paul R Mcdaniel
Reed Mcdaniel Construction Inc
Workers Comp Expired.
CCC1330719 Cert. Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Matt Forsyth 10/20/2021
Passed: Engineering - Setbacks Matt Forsyth 10/20/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 11/17/2021
Passed: Building - Slab Termite Uploaded Anthony Aslan 11/29/2021
Passed: Electrical - Temporary Service Anthony Aslan 1/12/2022
Release to power company Anthony Aslan 1/12/2022
Failed: Building - Lintel/Tie Beam Block Cells Were Pumped Without Being Inspected Need Letter From Engineer On Blockwork Matt Forsyth 1/21/2022
Failed: Building - Roof Decking Not Complete Schedule For Wed Matt Forsyth 2/21/2022
Passed: Building - Lintel/Tie Beam Matt Forsyth 2/22/2022
Passed: Building - Roof Decking Matt Forsyth 2/23/2022
Passed: Building - Framing Matt Forsyth 3/3/2022
Passed: Plumbing/Gas - 2nd Rough-In Tub Was Water Tested Matt Forsyth 3/3/2022
Passed: Electrical - 2nd Rough-In Matt Forsyth 3/3/2022
Failed: Mechanical - Rough In Not Complete Matt Forsyth 3/7/2022
Passed: Building - Insulation Matt Forsyth 3/10/2022
Passed: Mechanical - Rough In Matt Forsyth 3/10/2022
Passed: Electrical - Permanent Power Need Septic Release For Power - Rec'd 4.25.22 Matt Forsyth 4/7/2022
Release to power company Rec'd Eh 4.25.22 Matt Forsyth 4/25/2022
Septic Release Inspection Health Dept 4/25/2022
Failed: Building - Final Few Items Need To Be Addressed Matt Forsyth 5/12/2022
Passed: Building - Final Matt Forsyth 5/18/2022
Documents
File Name Date File Size
Truss Engineering 20211014 071746.pdf 2023.12.26 15.66MB
911 Sheet.pdf 2023.12.26 246.98kB
Application Information Page 20211014 071251.pdf 2023.12.26 371.38kB
Residential Or Commercial Checklist 20210831 132211.pdf 2023.12.26 2.54MB
Septic Approval Paperwork 20220425 075452.pdf 2023.12.26 431.34kB
Energy Code Forms 20211014 072046.pdf 2023.12.26 1.36MB
Power Release-release To Power Company 20220425.pdf 2023.12.26 39.02kB
Contractor Letter Of Authorization 20210831 132210.pdf 2023.12.26 333.20kB
Product Approval Code Specifications Form 20211014 071447.pdf 2023.12.26 333.39kB
Site Plan 20210831 132212.pdf 2023.12.26 213.14kB
Subcontractor Form 20210907 143450.pdf 2023.12.26 84.70kB
Win_20211129_09_37_05_pro 2021-11-29 09.37.49.852.jpg 2023.12.26 168.30kB
Power Release-electrical-temporary Service 20220112.pdf 2023.12.26 38.87kB
Manual J Forms 20211014 071546.pdf 2023.12.26 1.35MB
Septic Approval Paperwork 20210922 080347.pdf 2023.12.26 762.26kB
Certificate Of Occupancy 20220518.pdf 2023.12.26 68.93kB
Termite Treatment_initial 20211209 090846.pdf 2023.12.26 188.06kB
Leakage Report - Blow Door Test 2022-05-18 08.21.29.869.pdf 2023.12.26 14.18MB
Fpc 2022-05-18 09.30.26.942.jpg 2023.12.26 768.96kB
Property Appraiser Parcel Details Printed Page 20210831 132210.pdf 2023.12.26 165.12kB
Sealed Plans 50430 2021-09-21 09.45.07.928.pdf 2023.12.26 7.22MB
Owner And Contractor Signature Page 20210831 130923.pdf 2023.12.26 597.10kB
Recorded Notice Of Commencement 20210831 132210.pdf 2023.12.26 130.20kB
Recorded Deed 20210901 080325.pdf 2023.12.26 93.30kB
Original Permit 20210922.pdf 2023.12.26 42.95kB
Site Plan 20211014 071346.pdf 2023.12.26 177.55kB