Inspection |
Notes |
Performed By |
Date |
Rescheduled 10/13/2021:Plumbing/Gas - 1st Underground Rough–In |
|
Matt Forsyth |
10/12/2021 |
Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Matt Forsyth |
10/13/2021 |
Failed: Building - Monolithic Slab |
Need A Minimum Of A 6 Inch Concrete Form Around Garage Instead Of Four Inche |
Matt Forsyth |
11/3/2021 |
Passed: Engineering - Setbacks |
|
Matt Forsyth |
11/3/2021 |
Passed: Building - Monolithic Slab |
Item Addressed |
Matt Forsyth |
12/21/2021 |
Passed: Engineering - Setbacks |
|
Matt Forsyth |
12/21/2021 |
Passed: Electrical - Temporary Service |
|
Matt Forsyth |
12/21/2021 |
Release to power company |
|
Matt Forsyth |
12/21/2021 |
Passed: Building - Roof Decking |
|
Matt Forsyth |
1/6/2022 |
Passed: Building - Wall Sheathing |
|
Matt Forsyth |
1/6/2022 |
Passed: Electrical - 2nd Rough-In |
|
Matt Forsyth |
1/28/2022 |
Rescheduled 3/16/2022:Plumbing/Gas - 2nd Rough-In |
|
Matt Forsyth |
3/15/2022 |
Rescheduled 3/16/2022:Plumbing/Gas - Tub Set/Shower Pan |
|
Matt Forsyth |
3/15/2022 |
Failed: Plumbing/Gas - 2nd Rough-In |
Need A Precut Stud Installed In Between The Hot And Cold Water Supplying Water Heater. Because Of Notching Adjoining Stu |
Matt Forsyth |
3/16/2022 |
Passed: Plumbing/Gas - Tub Set/Shower Pan |
Tub Water Tested |
Matt Forsyth |
3/16/2022 |
Passed: Building - Insulation |
Walls Only |
Matt Forsyth |
3/16/2022 |
Failed: Mechanical - Rough In |
Several Boots In Ceiling Were Placed Within 3 Foot Of A Smoke Detector |
Matt Forsyth |
3/16/2022 |
Passed: Building - Framing |
|
Matt Forsyth |
3/16/2022 |
Passed: Mechanical - Rough In |
|
Matt Forsyth |
3/17/2022 |
Passed: Plumbing/Gas - 2nd Rough-In |
|
Matt Forsyth |
3/17/2022 |
Septic Release Inspection |
|
Health Dept |
4/18/2022 |
Passed: Electrical - Permanent Power |
Need Driveway Release |
Matt Forsyth |
5/9/2022 |
Release to power company |
|
Melissa Garber |
5/10/2022 |
Failed: Building - Final |
Need Ceiling Sealed Around Duckwork In Garage Electrical Panel Properly Labeled For Outside Receptacles Bath Gfci Not Reseting Switch Gfci Receptacle Under Island To Out Side Island Blowerdoor And Final Termite Treatment Needed |
Matt Forsyth |
5/23/2022 |
Rescheduled 6/23/2022:Building - Final |
|
Matt Forsyth |
6/22/2022 |
Passed: Building - Final |
Need Termite Treatment (final) |
Matt Forsyth |
6/23/2022 |
Passed: Building - Final |
|
Matt Forsyth |
6/24/2022 |