Permit Details

Permit Search

Permit

New Residential Construction

446 SW DUSK GLN
LAKE CITY, FL 32024

Permit #
000042736
Application #
50090
Status Completed
  1. Submitted Aug 18, 2021
  2. Issued Sep 13, 2021
  3. Expires Jan 2, 2023
  4. Completed Jul 6, 2022

Property

Parcel #
03235-007
Owner
Snipes Charles
Acres
20.27
Subdivision
Geniece Acres - Division Of Land (div0010)
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0380C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1.5
Heated Area (Sqft)
2976
Total Area (Sqft)
4698
Building Height
21
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0652
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Zoning Review - Reviewed
  4. Zoning Review - Reviewed
  5. Plan Review - Documents Required
  6. Plan Review - Plumbing Approved
  7. Plan Review - Mechanical Approved
  8. Plan Review - Electrical Approved
  9. Plan Review - Building Approved
  10. Plan Review - Reviewed
  11. Zoning Review - Reviewed
  12. Final Review - Reviewed
  13. Final Review - Payment Needed
  14. Permit Issued
  15. Final Review - Payment Needed

Contractors

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Robert Ogles Ii

    Ogles Roofing & Construction Llc

    License
    CCC1328699
    Title
    Cert Roofing
    Role
    Subcontractor
  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Anthony R Franks

    Franks & Lane Heating And Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Nov 18, 2021

    Passed: Building - Footer

    Inspected by Matt Forsyth

  2. Nov 18, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  3. Dec 22, 2021

    Rescheduled 1/3/2022:Building - Slab

    Inspected by Melissa Garber

  4. Dec 23, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  5. Jan 3, 2022

    Passed: Building - Slab

    Inspected by Matt Forsyth

  6. Jan 27, 2022

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  7. Feb 4, 2022

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Matt Forsyth

  8. Feb 4, 2022

    Passed: Building - Framing

    Inspected by Matt Forsyth

  9. Feb 4, 2022

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  10. Feb 24, 2022

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  11. Feb 24, 2022

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  12. Feb 24, 2022

    Passed: Plumbing/Gas - 2nd Rough-In

    Need Water Test On Bathtub. Can Do Water Test At Insulation Inspection

    Inspected by Matt Forsyth

  13. Mar 7, 2022

    Passed: Building - Insulation

    Inspected by Matt Forsyth

  14. May 11, 2022

    Failed: Electrical - Permanent Power

    Electrical Panel Not Labeled Or Made Up (breakers) Need Septic Release

    Inspected by Matt Forsyth

  15. May 12, 2022

    Passed: Electrical - Permanent Power

    Septic Needed

    Inspected by Matt Forsyth

  16. May 26, 2022

    Release to power company

    Inspected by Melissa Garber

  17. May 26, 2022

    Septic Release Inspection

    Inspected by Health Dept

  18. Jul 6, 2022

    Passed: Building - Final

    Need Proof Of Mechanical Ventilation On Hvac Ok To Start Moving In

    Inspected by Matt Forsyth

  19. Jul 6, 2022

    Passed: Building - Final

    Item Addressed

    Inspected by Matt Forsyth

Documents