Permit Details

Permit Search

Permit

New Residential Construction

389 SW UPSTAGE GLN
LAKE CITY, FL 32024

Permit #
000042646
Application #
49987
Status Completed
  1. Submitted Aug 5, 2021
  2. Issued Aug 30, 2021
  3. Expires Sep 6, 2022
  4. Completed Mar 14, 2022

Property

Parcel #
09280-150
Owner
Mcdermott Richard Alan & Mcdermott Pearl Ruth
Acres
5.46
Subdivision
Oaks Of Lake City Phase 1
Zoning
PRRD
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Subdivision Plat
Finished floor requirement
81'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0395C
In floodway
N
This is the construction of a
Accessory Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
1
Heated Area (Sqft)
798
Total Area (Sqft)
971
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
accessory dwelling
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0650
If Other, explain the use of the structure.
Mother- in-law suite next to main home
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Application pending.
  2. Point Review - Printed-Online Application
  3. Point Review - Reviewed
  4. Zoning Review - Corrections Needed
  5. Zoning Review - Reviewed
  6. Zoning Review - Documents Required
  7. Plan Review - Plumbing Approved
  8. Plan Review - Plumbing Approved
  9. Plan Review - Mechanical Approved
  10. Plan Review - Electrical Approved
  11. Plan Review - Building Approved
  12. Plan Review - Reviewed
  13. Zoning Review - Processing
  14. Zoning Review - Reviewed
  15. Final Review - Reviewed
  16. Final Review - Payment Needed
  17. Permit Issued

Contractors

  • Bryan Zecher

    Bryan Zecher Homes Inc

    License
    CBC1257343
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Robert Ogles Ii

    Ogles Roofing & Construction Llc

    License
    CCC1328699
    Title
    Cert Roofing
    Role
    Subcontractor

    County License & State License Expired.

  • Marcus Matthews

    Matthews Electric Llc

    License
    EC13005459
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Anthony R Franks

    Franks & Lane Heating And Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Sep 14, 2021

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Sep 14, 2021

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Oct 5, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  4. Oct 11, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  5. Nov 30, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Anthony Aslan

  6. Nov 30, 2021

    Passed: Building - Framing

    No Windows

    Inspected by Anthony Aslan

  7. Nov 30, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  8. Dec 10, 2021

    Cancelled: Building - Framing

    Inspected by Anthony Aslan

  9. Dec 10, 2021

    Cancelled: Building - Strapping

    Inspected by Anthony Aslan

  10. Dec 10, 2021

    Passed: Building - Wall Sheathing

    Inspected by Anthony Aslan

  11. Dec 10, 2021

    Passed: Electrical - 2nd Rough-In

    Need Another Outlet In Bedroom Window Wall

    Inspected by Anthony Aslan

  12. Dec 10, 2021

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  13. Dec 10, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  14. Dec 17, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  15. Jan 21, 2022

    Septic Release Inspection

    Inspected by Health Dept

  16. Mar 10, 2022

    Passed: Building - Final

    Inspected by Troy Crews

Documents