Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 192 SW RIVER RISE CT
FORT WHITE, FL 32038
Parcel #: 10021-016
Acres: 12.72
Owner: Flynn David P
Subdivision: Bussey Glen Unr
Zoning: A-3
Flood Zone: X
District: 4
Application #: 50012
Permit #: 000042616
Related Permit:
Submitted: Friday, October 29, 2021
Issued: Thursday, September 9, 2021
Expires: Thursday, January 5, 2023
Completed: Thursday, January 5, 2023
Status: Completed
Septic Release? Yes
Notes:
EXISTING STRUCTURE IS GARAGE/STORAGE AND THE STOVE MUST BE REMOVED BEFORE CO. ONLY ONE DWELLING ALLOWED PER ZONING RULES. SPECIAL TEMPORARY USE PERMIT FOR EXISTING MH FOR DAUGHTER - 5 YEARS TEMPORARY USE PERMIT 2108-52 APPROVED ~ENGINEER LETTER PROVIDED THE FINISHED FLOOR ELEVATION MUST BE A MINIMUM OF 61'. ELEVATION CONFIRMATION REC'D @ 62.85'
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 61.00'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0495C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1024
Total Area (Sqft) 1264
Building Height 15
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0626
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Review Notes
7/20/2021 Point Review - Received-Hard Copy Application TC: ENERGY CODE(?), ROOF OPTION, & MAUAN; "J"(?) NEEDED: EH
8/5/2021 Zoning Review - Documents Required NEEDED: EH, MANUAL J, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED
8/6/2021 Zoning Review - Documents Required NEEDED: EH, MANUAL J, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
8/6/2021 Zoning Review - Documents Required NEEDED: EH, MANUAL J, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/17/2021 Plan Review - Documents Required NEEDED: EH, MANUAL J, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/18/2021 Plan Review - Plumbing Approved NEEDED: EH, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/18/2021 Plan Review - Plumbing Approved NEEDED: EH, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/18/2021 Plan Review - Mechanical Approved NEEDED: EH, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/18/2021 Plan Review - Electrical Approved NEEDED: EH, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/18/2021 Plan Review - Building Approved NEEDED: EH, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/18/2021 Plan Review - Reviewed NEEDED: EH, STUP PAPERWORK BEFORE THIS PERMIT CAN BE ISSUED *IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED. 911 ADDRESS WILL BE NEEDED BECAUSE THE STRUCTURE WILL BE IN A DIFFERENT LOCATION FROM THE EXISTING HOME/ADDRESS
8/23/2021 Zoning Review - Reviewed NEEDED: ENVIRONMENTAL HEALTH *ZONING NOTES: IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
8/24/2021 Final Review - Complete *ZONING NOTES: IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
8/24/2021 Permit Issued Permit #000042616 created and approved.
9/9/2021 Permit reissued to reflect updated information.
11/14/2022 Final Review - Payment Needed *ZONING NOTES: IF MINIMUM FLOOR ELAVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED.
Contractors
Name/ Business License Title Role
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Donald R Davis
High Springs Electric Inc
CAC1815367 Class B A/c Subcontractor
George N Degler Jr
A Proud Plumber Llc
CFC1427133 Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Failed: Plumbing/Gas - 1st Underground Rough–In Air Trapped In Toilets And Other Stub Ups. Anthony Aslan 10/6/2021
Passed: Electrical - 1st Underground Rough–In Anthony Aslan 10/8/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 10/8/2021
Passed: Engineering - Setbacks Anthony Aslan 10/14/2021
Passed: Building - Monolithic Slab Anthony Aslan 10/14/2021
Passed: Building - Slab Anthony Aslan 10/22/2021
Failed: Building - Roof Decking Check Nails Lose Sheathing Anthony Aslan 3/29/2022
Failed: Building - Wall Sheathing Marked Red Missing Nails Anthony Aslan 3/29/2022
Passed: Building - Roof Decking Corrections Made Anthony Aslan 3/31/2022
Passed: Building - Wall Sheathing Corrections Made Anthony Aslan 3/31/2022
Failed: Building - Framing Need Stud Packs Under Doubled Truss Anthony Aslan 4/14/2022
Passed: Building - Framing Corrections Made Anthony Aslan 4/20/2022
Failed: Plumbing/Gas - 2nd Rough-In R602.6drilling And Notching Of Studs. drilling And Notching Of Studs Shall Be In Accordance With The Following: 1.notching. Any Stud In An Exterior Wall Or Bearing Partition Shall Be Permitted To Be Cut Or Notched To A Depth Not Exceeding 25 Percent Of Its Width. Studs In Nonbearing Partitions Shall Be Permitted To Be Notched To A Depth Not To Exceed 40 Percent Of A Single Stud Width. 2.drilling. Any Stud Shall Be Permitted To Be Bored Or Drilled, Provided That The Diameter Of The Resulting Hole Is Not More Than 60 Percent Of The Stud Width, The Edge Of The Hole Is Not More Than 5/8 Inch (16 Mm) To The Edge Of The Stud, And The Hole Is Not Located In The Same Section As A Cut Or Notch. Studs Located In Exterior Walls Or Bearing Partitions Drilled Over 40 Percent And Up To 60 Percent Shall Be Doubled With Not More Than Two Successive Doubled Studs Bored. See Figures R602.6(1) And R602.6(2). Anthony Aslan 6/2/2022
Passed: Electrical - 2nd Rough-In Anthony Aslan 6/2/2022
Failed: Mechanical - Rough In M1501.1outdoor Discharge. the Air Removed By Every Mechanical Exhaust System Shall Be Discharged To The Outdoors In Accordance With Section M1506.3. Air Shall Not Be Exhausted Into An Attic, Soffit, Ridge Vent Or Crawl Space. m1506.3exhaust Openings. air Exhaust Openings Shall Terminate Not Less Than 3 Feet (914 Mm) From Property Lines; 3 Feet (914 Mm) From Operable And Nonoperable Openings Into The Building And 10 Feet (3048 Mm) From Mechanical Air Intakes Except Where The Opening Is Located 3 Feet (914 Mm) Above The Air Intake. Openings Shall Comply With Sections R303.5.2 And R303.6. m1305.1.3appliances In Attics. attics Containing Appliances Shall Be Provided With An Opening And A Clear And Unobstructed Passageway Large Enough To Allow Removal Of The Largest Appliance, But Not Less Than 30 Inches (762 Mm) High And 22 Inches (559 Mm) Wide And Not More Than 20 Feet (6096 Mm) Long Measured Along The Centerline Of The Passageway From The Opening To The Appliance. The Passageway Shall Have Continuous Solid Flooring In Accordance With Chapter 5 Not Less Than 24 Inches (610 Mm) Wide. A Level Service Space Not Less Than 30 Inches (762 Mm) Deep And 30 Inches (762 Mm) Wide Shall Be Present Along All Sides Of The Appliance Where Access Is Required. The Clear Access Opening Dimensions Shall Be Not Less Than Of 20 Inches By 30 Inches (508 Mm By 762 Mm), And Large Enough To Allow Removal Of The Largest Appliance. Anthony Aslan 6/2/2022
Passed: Mechanical - Rough In Check Bath Vent At Final Location Anthony Aslan 6/7/2022
Passed: Plumbing/Gas - 2nd Rough-In Need Letter For Stud With T Brace. Anthony Aslan 6/7/2022
Passed: Building - Insulation Anthony Aslan 6/13/2022
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 11/16/2022
Release to power company Melissa Garber 11/30/2022
Septic Release Inspection Health Dept 11/30/2022
Passed: Building - Final Need Breaker Lock Out On A/c Breaker, Seal Tight On Wall And Duct Wire Outside, Fresh Air Anthony Aslan 12/20/2022
Certificate-Release Certificate Rec'cd Pictures Of Corrections Anthony Aslan 1/5/2023
Documents
File Name Date File Size
Power Release-release To Power Company 20221130.pdf 2025.07.05 11.32kB
Updated Permit 20210909.pdf 2025.07.05 49.96kB
Lidar 50012 2021-08-05 17.00.42.201.pdf 2025.07.05 182.23kB
Product Approval Code Specifications Form 20211207 114046.pdf 2025.07.05 235.65kB
Flynn Noc 2021-08-24 12.02.34.526.pdf 2025.07.05 118.43kB
Structural Analysis Report 20220418 074046.pdf 2025.07.05 189.84kB
Property Appraiser Parcel Details Printed Page 20211207 114047.pdf 2025.07.05 290.33kB
Termite Treatment_initial 20220418 074146.pdf 2025.07.05 223.56kB
Application Information Page 20211207 113847.pdf 2025.07.05 257.75kB
Owner And Contractor Signature Page 20211207 113846.pdf 2025.07.05 353.66kB
Septic Approval Paperwork 20211207 113847.pdf 2025.07.05 299.94kB
Recorded Deed 20211207 113946.pdf 2025.07.05 464.18kB
Subcontractor Form 20211207 113947.pdf 2025.07.05 375.55kB
Zoning Approval Documents 2021-10-29 12.43.07.798.pdf 2025.07.04 685.09kB
Owner Disclosure Statement 20211207 113946.pdf 2025.07.04 720.50kB
Manual J Forms 20211207 114247.pdf 2025.07.04 660.36kB
Residential Or Commercial Checklist 20211207 114047.pdf 2025.07.04 1.47MB
Elevation Letter 188 Sw River Rise Court Fort White Fl 08-25-21 2021-09-09 11.38.45.403.pdf 2025.07.04 1.31MB
Energy Code Forms 20211207 114246.pdf 2025.07.04 2.65MB
Truss Engineering 20211207 114146.pdf 2025.07.04 3.38MB
42616 Plans.pdf 2025.07.03 8.81MB
Original Permit 20210824.pdf 2025.06.22 49.68kB
42616 Breaker Lockout 2023-01-05 12.09.34.184.jpg 2025.06.20 12.41kB
42616 Fresh Air 2023-01-05 12.09.34.402.jpg 2025.06.20 29.09kB
42616 Line Set 2023-01-05 12.09.34.590.jpg 2025.06.20 30.12kB
Certificate Of Occupancy 20230105.pdf 2023.12.23 62.93kB
Surveyor Letter Giving The Finished Floor Elevation 2022-03-28 13.47.54.577.pdf 2023.12.23 60.69kB