Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 200 NW TURKEY CREEK WAY
LAKE CITY, FL 32055
Parcel #: 02279-122
Acres: 0.24
Owner: Woodborough North Llc
Subdivision: Turkey Creek Unit 1
Zoning: PRD
Flood Zone: X
District: 1
Application #: 49565
Permit #: 000042581
Related Permit: Culvert: 000042582
Submitted: Friday, December 17, 2021
Issued: Friday, December 17, 2021
Expires: Thursday, July 28, 2022
Completed: Thursday, July 28, 2022
Status: Completed
Septic Release? Yes
Notes:
FINISHED FLOOR ELEVATION DETERMINED BY ENGINEER-- SEE ATTACHED DOCUMENT-- PERMIT UPDATED 12/17/2021 ELEVATION CONFIRMATION REC'D @ 158.54'
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 158.54'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0283D
This is the construction of a Single Family Dwelling
Setbacks Front 20'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 20'
Stories 1
Heated Area (Sqft) 1523
Total Area (Sqft) 2160
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title SINGLE FAMILY DWELLING
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0612
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
6/8/2021 Point Review - Received-Hard Copy Application
6/8/2021 Zoning Review - Reviewed NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
6/23/2021 Plan Review - Plumbing Approved NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
6/23/2021 Plan Review - Electrical Approved NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
6/23/2021 Plan Review - Mechanical Approved NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
6/23/2021 Plan Review - Building Approved NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
6/23/2021 Plan Review - Reviewed NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
6/23/2021 Final Review - Documents Required NEED: ENVIRONMENTAL HEALTH SEPTIC APPROVED PERMIT
8/19/2021 Permit Issued Permit #000042581 created and approved.
12/17/2021 Permit reissued to reflect updated information.
12/17/2021 Permit reissued to reflect updated information.
6/15/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
James Lipscomb
Lipscomb & Eagle Development Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CBC1253543 Building Contractor Contractor
Mervin L Hines
Hines Electrical & Communication Inc
EC13003393 Electrical Contractor Subcontractor
David E Hall
David Hall's Air Cond & Heating Svc,inc.
CAC057424 Class B A/c Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CCC1329482 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 8/23/2021
Passed: Building - Footer Need Ground Wire On Footer Steel Prior To Pour Troy Crews 9/14/2021
Passed: Engineering - Setbacks Confirm With Surveyor Troy Crews 9/14/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 11/12/2021
Passed: Building - Slab Anthony Aslan 11/17/2021
Passed: Building - Wall Sheathing Anthony Aslan 12/20/2021
Passed: Building - Roof Decking Roof Eyebrow Over Garage Missing Nails Anthony Aslan 12/20/2021
Passed: Building - Framing Missing Anchor Bolts At Bottom Plate Splice Anthony Aslan 1/11/2022
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 2/10/2022
Failed: Mechanical - Rough In Gasket Missing On Some Supply Boots, Exhaust Vent Piping Can Not Be Within 3'ft Of Operable And Non-operable Openings To House, Anthony Aslan 2/10/2022
Passed: Electrical - 2nd Rough-In Service Wire Exterior Wall Top Plate Notched More Than 50% Of Bearing Top Plate. Anthony Aslan 2/10/2022
Passed: Mechanical - Rough In Corrections Made Anthony Aslan 2/17/2022
Passed: Building - Insulation Anthony Aslan 3/1/2022
Passed: Engineering - Final Driveway Inspection Was Made Only Of The Construction Of The Culvert And Related Concrete Work. Inspection Did Not Include The Surface Water Management System, Ditch Work, Slopes, Elevations, Or Any Other Matter Concerning Drainage At Or Around The Subject Property. This Document Shall Not Be Construed To Reflect Any Opinion Of The Inspector Other Than The Construction Of The Culvert In Accordance With The Permit. Smith, Blake 6/1/2022
Septic Release Inspection Health Dept 6/2/2022
Rescheduled 6/7/2022:Building - Final Anthony Aslan 6/3/2022
Cancelled: Building - Final Matt Forsyth 6/6/2022
Cancelled: Building - Final Anthony Aslan 6/15/2022
Passed: Electrical - Permanent Power Anthony Aslan 6/15/2022
Release to power company Anthony Aslan 6/15/2022
Passed: Building - Final Anthony Aslan 7/28/2022
Documents
File Name Date File Size
Updated Permit 20211217.pdf 2025.07.05 29.53kB
Site Plan 20220210 084246.pdf 2025.07.05 105.47kB
Lidar Map Lot 22 2021-06-08 16.08.35.536.pdf 2025.07.05 188.63kB
Corporate Articles Listing The Owner Or Poa Form Or Executor Documents 20220210 084547.pdf 2025.07.05 92.48kB
Surveyor Letter Giving The Finished Floor Elevation 20211208 101106.pdf 2025.07.05 94.68kB
City Or County Utility Availability Letter 20220210 084448.pdf 2025.07.05 165.60kB
Subcontractor Form 20220210 084146.pdf 2025.07.05 189.25kB
Application Information Page 20220210 083846.pdf 2025.07.05 238.03kB
Recorded Notice Of Commencement 20220210 084547.pdf 2025.07.05 241.67kB
Structural Analysis Report 20211117 125446.pdf 2025.07.05 236.82kB
Blower Door Test Results 20220729 084646.pdf 2025.07.05 313.92kB
Recorded Deed 20220210 084646.pdf 2025.07.05 316.01kB
Termite Treatment_initial 20211117 125450.pdf 2025.07.05 313.40kB
Owner And Contractor Signature Page 20220210 083946.pdf 2025.07.05 361.63kB
Septic Approval Paperwork 20220210 093152.pdf 2025.07.05 325.71kB
Property Appraiser Parcel Details Printed Page 20220210 084347.pdf 2025.07.05 476.80kB
911 Address Form 20220210 084247.pdf 2025.07.05 538.92kB
Manual J Forms 20220210 090948.pdf 2025.07.04 853.92kB
Elevation Letter 23-3s-16-02279-122 Lake City Fl 2021-12-17 12.27.06.886.pdf 2025.07.04 1.15MB
Energy Code Forms 20220210 090846.pdf 2025.07.04 1.23MB
Residential Or Commercial Checklist 20220210 090746.pdf 2025.07.04 1.86MB
Truss Engineering 20220210 085046.pdf 2025.07.04 2.10MB
Truss Engineering 20220210 090247.pdf 2025.07.04 13.79MB
42581 Plans.pdf 2025.07.03 8.28MB
42581 Final Termite 2022-06-15 11.35.00.843.jpg 2025.06.20 89.27kB
Turkey Creek Unit 1 Prd Lot 22 2021-06-08 15.54.45.545.pdf 2023.12.23 2.95MB
Certificate Of Occupancy 20220728.pdf 2023.12.23 62.32kB
Power Release-electrical-permanent Power 20220615.pdf 2022.06.15 38.82kB
Original Permit 20210819.pdf 2021.08.19 43.16kB