Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 826 NW ASH DR
LAKE CITY, FL 32055
Parcel #: 02215-014
Acres: 9.05
Owner: Hadley John
Subdivision:
Zoning: A-3
Flood Zone: A
District: 3
Application #: 49944
Permit #: 000042553
Related Permit:
Submitted: Thursday, July 15, 2021
Issued: Monday, August 16, 2021
Expires: Friday, March 21, 2025
Completed: Friday, March 21, 2025
Status: Completed
Septic Release? Yes
Notes:

Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 768
Total Area (Sqft) 928
Stories 1
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 24-0576
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0280D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Review Notes
7/14/2021 Application pending.
7/16/2021 Point Review - Printed-Online Application NEEDED: *911 ADDRESS *OWNER DISCLOSURE STATEMENT *PRODUCT APPROVAL FORM *RES CHECKLIST *TRUSS ENGINEERING
7/16/2021 Point Review - Reviewed NEEDED: *911 ADDRESS *OWNER DISCLOSURE STATEMENT *PRODUCT APPROVAL FORM *RES CHECKLIST *TRUSS ENGINEERING
7/30/2021 Zoning Review - Reviewed *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/9/2021 Plan Review - Plumbing Approved *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/9/2021 Plan Review - Mechanical Approved *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/9/2021 Plan Review - Electrical Approved *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/9/2021 Plan Review - Building Approved *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/9/2021 Plan Review - Reviewed *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/11/2021 Zoning Review - Reviewed *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/12/2021 Final Review - Reviewed *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/12/2021 Final Review - Payment Needed *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
8/16/2021 Permit Issued Permit #000042553 created and approved.
10/22/2024 Final Review - Payment Needed *IF MINIMUM FLOOR ELEVATION CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED - LW
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Matt Forsyth 8/18/2021
Release to power company Matt Forsyth 8/18/2021
Cancelled: Electrical - Temporary Service Troy Crews 8/18/2021
Passed: Building - Footer Troy Crews 1/11/2022
Passed: Engineering - Setbacks Troy Crews 1/11/2022
Passed: Building - Lintel/Tie Beam Stem Walls Troy Crews 6/9/2022
Passed: Building - Masonry Wall Reinforcing Troy Crews 6/9/2022
Passed: Building - Framing Floor Framing Troy Crews 11/23/2022
Cancelled: Building - Slab Troy Crews 11/23/2022
Passed: Building - Framing Troy Crews 4/3/2023
Passed: Building - Wall Sheathing Troy Crews 4/3/2023
Passed: Building - Roof Decking Troy Crews 4/19/2023
Passed: Building - Rated Assembly Fastening Troy Crews 10/2/2023
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 3/8/2024
Passed: Plumbing/Gas - Tub Set/Shower Pan Troy Crews 3/8/2024
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 3/8/2024
Passed: Electrical - 1st Underground Rough–In Troy Crews 6/27/2024
Passed: Electrical - 2nd Rough-In Troy Crews 6/27/2024
Passed: Electrical - Permanent Power Troy Crews 10/7/2024
Passed: Building - Insulation Troy Crews 10/7/2024
Septic Release Inspection Health Dept 10/7/2024
Release to power company Troy Crews 10/8/2024
Passed: Mechanical - Rough In Troy Crews 3/19/2025
Certificate-Release Certificate Troy Crews 3/21/2025
Passed: Building - Final Troy Crews 3/21/2025
Documents
File Name Date File Size
Certificate Of Occupancy 20250321.pdf 2025.03.24 54.39kB
Hadley Blower Door 2025-03-21 07.23.53.37.jpg 2025.03.21 372.73kB
Power Release-electrical-permanent Power 20241008.pdf 2024.10.08 38.86kB
Hadley Eh 24-0576 2024-10-08 07.58.45.706.pdf 2024.10.08 1.35MB
Recorded Deed 20210714 161948.pdf 2023.12.24 82.05kB
Subcontractor Form 20210715 172233.pdf 2023.12.24 125.85kB
Septic Approval Paperwork 20210715 172231.pdf 2023.12.24 1.34MB
Structural Engineering And Wind Load Calculations 20210715 172231.pdf 2023.12.24 4.40MB
Approved Truss Plans 49944 2021-08-09 07.16.26.596.pdf 2023.12.24 631.43kB
Residential Or Commercial Checklist 20210719 122212.pdf 2023.12.24 624.54kB
Owner And Contractor Signature Page 20210715 171629.pdf 2023.12.24 125.32kB
Energy Code Forms 20210715 172600.pdf 2023.12.24 234.71kB
Architectural Plans 20210715 172230.pdf 2023.12.24 2.10MB
Owner Disclosure Statement 20210719 111949.pdf 2023.12.24 230.17kB
Recorded Noc 2021-08-05 13.30.23.32.pdf 2023.12.24 43.90kB
Site Plan 20210730 100148.pdf 2023.12.24 308.99kB
Power Release-electrical-temporary Service 20210818.pdf 2023.12.24 38.71kB
Property Appraiser Parcel Details Printed Page 20210715 172231.pdf 2023.12.24 287.37kB
Original Permit 20210816.pdf 2023.12.24 132.36kB
911 Address Form 20210720 112226.pdf 2023.12.24 129.10kB
Truss Engineering 20210719 121538.pdf 2023.12.24 586.43kB
Approved Structural 49944 2021-08-09 07.20.42.109.pdf 2023.12.24 4.44MB
Lidar 49944 2021-07-30 10.36.50.434.pdf 2023.12.24 150.78kB
Product Approval Code Specifications Form 20210719 113742.pdf 2023.12.24 140.94kB
Manual J Forms 20210715 172601.pdf 2023.12.24 181.62kB
Hadley Termite 2022-11-23 14.35.20.382.jpg 2023.12.24 1.87MB