Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 292 SW EMERALD ST
LAKE CITY, FL 32024
Parcel #: 02919-147
Acres: 0.52
Owner: Podlaszewski Edward & Maria & Andrew
Subdivision: Emerald Forest Phase 2
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 50193
Permit #: 000042552
Related Permit:
Submitted: Thursday, August 12, 2021
Issued: Monday, August 16, 2021
Expires: Thursday, September 9, 2021
Completed: Thursday, September 9, 2021
Status: Completed
Septic Release? na
Notes:
PICS AND AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0289D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2300
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL 10124 R 2 8
Product Manufacturer GAF
Product Description Timberline architectural shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
8/5/2021 Application pending.
8/12/2021 Final Review - Corrections Needed
8/13/2021 Final Review - Payment Needed
8/16/2021 Permit Issued
Contractors
Name/ Business License Title Role
Caleb Laughlin
Precision Exteriors Llc
County License & State License & Liability Insurance Expired.
CCC1327718 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 8/30/2021
Passed: Re-Roof - Final Matt Forsyth 9/9/2021