| Finished floor requirement |
|
| Fema map number |
12023C0284D |
| Type Roofing Job |
Overlay with Metal |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
No deck replacement. |
| Type of structure |
Mobile Home |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
2300 |
| No. of Stories |
1 |
| Roof Pitch |
2:12 to 4:12 |
| Is the existing roof being removed? |
No |
| Explain if not removing the existing roofing material? |
Metal roof-over. |
| Type of New Roofing Product |
Metal |
| Florida Product Approval Number |
4595.17 |
| Product Manufacturer |
Tric-County Metals |
| Product Description |
Ultra-Rib Roof Panel, Min. 29 Ga. Steel, 36” Wide, through fastened roof panel over 1x4 wood purlins over one layer of asphalt shingles (optional) over min. 15/32” APA Plywood decking. Non-Structural Application. |
| Building Code Edition |
2020 Florida Building Code 7th Edition and Florida Statute 553.844 |
| Sealed roof decking options: (Must select an option.) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Ventilation: |
Ridge Vent |
| Flashing: |
Replace All |
| Drip Edge: |
Replace All |
| Valley Treatment: |
New Metal |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |