Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit
Address 2118 SW LONCALA LOOP
FORT WHITE, FL 32038
Parcel #: 00502-102
Acres: 5.01
Owner: Maurice Erickson
Subdivision: Ichetucknee Forest Phase 2
Zoning: ESA-2
Flood Zone: X
District: 2
Application #: 50205
Permit #: 000042506
Related Permit:
Submitted: Friday, August 6, 2021
Issued: Friday, August 6, 2021
Expires: Wednesday, September 22, 2021
Completed: Wednesday, September 22, 2021
Status: Completed
Septic Release? na
Notes:
PICS & AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0460C
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Remove existing roof and install asphalt shingles
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 14
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL5444-R16
Product Manufacturer Certainteed
Product Description 3-tab, 4-tab, strip (no-cut-outs), laminated and architectural asphalt roof shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Unvented
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
8/6/2021 Application pending.
8/6/2021 Final Review - Payment Needed
8/6/2021 Permit Issued Permit #000042506 created and approved.
Contractors
Name/ Business License Title Role
Daniel Dufresne
Covenant Roofing & Construction Inc
CCC1332763 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Anthony Aslan 9/8/2021
Passed: Re-Roof - Final Anthony Aslan 9/22/2021