Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 320 SW BELLFLOWER DR
LAKE CITY, FL 32024
Parcel #: 02731-054
Acres: 0.30
Owner: The Preserve At Laurel Lake Inc
Subdivision: Preserve At Laurel Lake Unit 1
Zoning: PRD
Flood Zone: X
District: 3
Application #: 49688
Permit #: 000042413
Related Permit: Culvert Waiver: 000042414
Submitted: Thursday, October 28, 2021
Issued: Tuesday, July 27, 2021
Expires: Friday, March 18, 2022
Completed: Friday, March 18, 2022
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D @ 113.4'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 112.1'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 2281
Total Area (Sqft) 3184
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
6/21/2021 Zoning Review - Reviewed *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
6/21/2021 Point Review - Received-Hard Copy Application *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
6/21/2021 Point Review - Reviewed *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Plan Review - Plumbing Approved *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Plan Review - Mechanical Approved *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Plan Review - Electrical Approved *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Plan Review - Building Approved *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Plan Review - Reviewed *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Zoning Review - Reviewed *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/1/2021 Final Review - Documents Required *ROOFING UNDERLAYMENT OPTION-- MG SENT EMAIL 6/21 *RATHEL UPDATED LIABILITY AND WORKERS COMP NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/21/2021 Final Review - Payment Needed NEEDED PRIOR TO INSPECTIONS: *RECORDED NOC
7/27/2021 Permit Issued Permit #000042413 created and approved.
2/16/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Aaron Simque
Aaron Simque Homes Inc
County License & State License & Liability Insurance & Workers Comp Expired.
RR282811879 Residential Contractor Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
Workers Comp Expired.
CAC1819412 Cert. A/c Class “b” Subcontractor
Ralph W Laverdure
Rwl Roofing,llc.
CCC1328590 Roofing Contractor Subcontractor
Kenneth Ault
Kenneth Edward Ault Plumbing Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1429807 Cert. Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 8/13/2021
Passed: Engineering - Setbacks Done By Surveyor Per Contractor Troy Crews 8/13/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Put Pressure Back On Water Lines Prior To Slab Inspection. Troy Crews 9/16/2021
Cancelled: Plumbing/Gas - 1st Underground Rough–In Troy Crews 9/16/2021
Passed: Building - Slab Troy Crews 9/20/2021
Passed: Building - Roof Decking Troy Crews 10/28/2021
Passed: Building - Wall Sheathing Troy Crews 10/28/2021
Passed: Building - Framing Troy Crews 11/2/2021
Cancelled: Building - Wall Sheathing Troy Crews 11/2/2021
Passed: Electrical - 2nd Rough-In Troy Crews 11/2/2021
Failed: Mechanical - Rough In No Range Hood Duct Installed Troy Crews 11/2/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 11/2/2021
Passed: Mechanical - Rough In Troy Crews 11/16/2021
Passed: Building - Insulation Troy Crews 11/29/2021
Passed: Electrical - Permanent Power Troy Crews 2/17/2022
Release to power company Troy Crews 2/17/2022
Failed: Building - Final Not Complete Plumbing Ac Thermostat Troy Crews 3/17/2022
Passed: Building - Final Troy Crews 3/18/2022
Documents
File Name Date File Size
Power Release-electrical-permanent Power 20220217.pdf 2025.07.05 11.34kB
Certificate Of Occupancy 20220318.pdf 2025.07.05 53.21kB
Corporate Articles Listing The Owner Or Poa Form Or Executor Documents 20210804 110346.pdf 2025.07.05 121.80kB
Site Plan 20210804 110446.pdf 2025.07.05 158.16kB
Surveyor Letter Giving The Finished Floor Elevation 20211029 112746.pdf 2025.07.05 138.99kB
911 Address Form 20210804 110447.pdf 2025.07.05 145.93kB
City Or County Utility Availability Letter 20210804 110447.pdf 2025.07.05 159.48kB
Roof Inspection Affidavit By Contractor 20210730 100948.pdf 2025.07.05 180.77kB
Product Approval Code Specifications Form 20210804 110648.pdf 2025.07.05 229.01kB
Application Information Page 20210804 110246.pdf 2025.07.05 255.47kB
Bnz Invoice 2022-03-09.pdf 2025.07.05 184.88kB
Recorded Notice Of Commencement 20210728 043223.pdf 2025.07.05 277.49kB
Plumbing Sub Vf.pdf 2025.07.05 432.46kB
Owner And Contractor Signature Page 20210804 110247.pdf 2025.07.05 370.65kB
Recorded Deed 20210804 110346.pdf 2025.07.05 291.96kB
Columbia County Property Appraiser 2021-06-21 17.35.23.796.pdf 2025.07.05 450.40kB
Mechanical, Roofing, Electrical Sub Vf.pdf 2025.07.04 642.14kB
Subcontractor Form 20220310 110245.pdf 2025.07.04 868.37kB
Manual J Forms 20210804 110746.pdf 2025.07.04 906.20kB
Residential Or Commercial Checklist 20210804 110546.pdf 2025.07.04 1.45MB
Bdt Simque Lot 54 42413 2022-03-17 20.49.58.560.pdf 2025.07.04 350.97kB
Energy Code Forms 20210804 110646.pdf 2025.07.04 2.91MB
Win_20210920_10_59_34_pro 2021-09-20 11.00.59.137.jpg 2025.06.20 167.20kB
Truss Engineering.pdf 2025.06.19 12.89MB
Plans 2021-08-04 13.35.33.779.pdf 2023.12.23 5.63MB
Original Permit 20210727.pdf 2021.07.27 43.15kB