Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 304 SW BELLFLOWER DR
LAKE CITY, FL 32024
Parcel #: 02731-055
Acres: 0.37
Owner: The Preserve At Laurel Lake Inc
Subdivision: Preserve At Laurel Lake Unit 1
Zoning: PRD
Flood Zone: X
District: 3
Application #: 49702
Permit #: 000042411
Related Permit: Culvert Waiver: 000042412
Submitted: Thursday, October 28, 2021
Issued: Tuesday, July 27, 2021
Expires: Tuesday, August 30, 2022
Completed: Tuesday, August 30, 2022
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D @ 113.1'
Job Details
Finished floor requirement
Fema map number 12023C0283D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Replace wood as needed.
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 50
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R8
Product Manufacturer TAMKO
Product Description HERITAGE
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
6/21/2021 Point Review - Received-Hard Copy Application
6/21/2021 Point Review - Reviewed
6/24/2021 Zoning Review - Reviewed
7/9/2021 Plan Review - Plumbing Approved
7/9/2021 Plan Review - Mechanical Approved
7/9/2021 Plan Review - Electrical Approved
7/9/2021 Plan Review - Building Approved
7/9/2021 Plan Review - Reviewed
7/15/2021 Zoning Review - Reviewed
7/16/2021 Final Review - Documents Required
7/21/2021 Final Review - Payment Needed
7/27/2021 Permit Issued
2/17/2022 Final Review - Payment Needed
3/17/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Aaron Simque
Aaron Simque Homes Inc
County License & State License & Liability Insurance & Workers Comp Expired.
RR282811879 Residential Contractor Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing,llc.
CCC1328590 Roofing Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
CAC1819412 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 8/20/2021
Passed: Engineering - Setbacks Need To Be Confirmed By Surveyor Troy Crews 8/20/2021
Passed: Building - Footer Troy Crews 9/10/2021
Passed: Engineering - Setbacks Shifted House To The Rear Of Lot To Meet Setbacks Troy Crews 9/10/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 9/24/2021
Passed: Building - Slab Troy Crews 10/5/2021
Passed: Building - Roof Decking Troy Crews 10/28/2021
Passed: Building - Wall Sheathing Troy Crews 10/28/2021
Failed: Building - Framing No Porch Post Strapping, No Anchor Bolts, Not Complete Overall. Troy Crews 11/2/2021
Failed: Electrical - 2nd Rough-In No Wiring Done. Troy Crews 11/2/2021
Failed: Mechanical - Rough In No Mechanical Done. Troy Crews 11/2/2021
Failed: Plumbing/Gas - 2nd Rough-In No Plumbing Ready. Troy Crews 11/2/2021
Failed: Mechanical - Rough In Bath Fan Ducts Disconnected And Short At Soffit Call Back In With Insulation. Troy Crews 11/16/2021
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 11/16/2021
Passed: Building - Framing Troy Crews 11/16/2021
Passed: Building - Strapping Troy Crews 11/16/2021
Passed: Building - Wall Sheathing Troy Crews 11/16/2021
Passed: Electrical - 2nd Rough-In Troy Crews 11/16/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 11/16/2021
Passed: Building - Insulation Bath Fan Duct Not Repaired Need Inspection Before Drywall, Mechanical Troy Crews 11/29/2021
Passed: Electrical - Permanent Power Troy Crews 2/18/2022
Release to power company Troy Crews 2/18/2022
Failed: Building - Final No One Home Owner Needs To Be On Site For Inspection Belongings Are In The House Troy Crews 8/23/2022
Passed: Building - Final Troy Crews 8/30/2022
Documents
File Name Date File Size