Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 171 NW GOBBLER DR
LAKE CITY, FL 32055
Parcel #: 02279-128
Acres: 0.25
Owner: Main Blvd Rental Llc
Subdivision: Turkey Creek Unit 1
Zoning: PRD
Flood Zone: X
District: 1
Application #: 48878
Permit #: 000042326
Related Permit: Culvert: 000042327
Submitted: Thursday, March 3, 2022
Issued: Wednesday, July 14, 2021
Expires: Thursday, April 14, 2022
Completed: Thursday, April 14, 2022
Status: Completed
Septic Release? Yes
Notes:
CHECK FRONT AND SIDE SETBACKS IN FIELD ELEVATION CONFIRMATION REC'D @ 160.73
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 160.25
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0283D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 20'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 20'
Stories 1
Heated Area (Sqft) 1736
Total Area (Sqft) 2684
Building Height 21
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0573
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/30/2021 Point Review - Status Cleared
3/31/2021 Zoning Review - Reviewed
4/12/2021 Plan Review - Reviewed
4/19/2021 Zoning Review - Reviewed
4/19/2021 Final Review - Documents Required
6/18/2021 Final Review - Documents Required
7/8/2021 Final Review - Corrections Needed
7/14/2021 Permit Issued
3/3/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
James Lipscomb
Lipscomb & Eagle Development Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CBC1253543 Building Contractor Contractor
Mervin L Hines
Hines Electrical & Communication Inc
Workers Comp Expired.
EC13003393 Electrical Contractor Subcontractor
David E Hall
David Hall's Air Cond & Heating Svc,inc.
CAC057424 Class B A/c Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Kevin L Bedenbaugh Jr
Plumb Level Construction Co Llc
CCC1329482 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 7/14/2021
Passed: Building - Footer Anthony Aslan 7/21/2021
Passed: Engineering - Setbacks Tight Lot Lines Anthony Aslan 7/21/2021
Passed: Electrical - 1st Underground Rough–In Anthony Aslan 8/13/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 8/13/2021
Cancelled: Building - Slab Anthony Aslan 8/26/2021
Passed: Building - Slab Anthony Aslan 8/30/2021
Passed: Building - Roof Decking Anthony Aslan 9/29/2021
Failed: Building - Wall Sheathing Red Marker Marking Missing Nails Anthony Aslan 9/29/2021
Passed: Building - Wall Sheathing Left Side Window With X Missing Nails. Anthony Aslan 10/4/2021
Passed: Building - Framing Check Anchor Bolts Anthony Aslan 10/13/2021
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 12/3/2021
Failed: Electrical - 2nd Rough-In Service Feed More Than 50% Hole On Top Plate Need Reinforced Strap Anthony Aslan 12/3/2021
Failed: Mechanical - Rough In Master Closet Boot Missing Gasket, Dryer Vent More Than 50% Top Plate Need Re-enforced Strap Anthony Aslan 12/3/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 12/9/2021
Passed: Mechanical - Rough In Anthony Aslan 12/9/2021
Passed: Building - Insulation Anthony Aslan 12/10/2021
Passed: Engineering - Final Driveway Smith, Blake 2/17/2022
Release to power company Septic Rec'd-- Will Run Report Monday Melissa Garber 3/4/2022
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 3/4/2022
Septic Release Inspection Health Dept 3/7/2022
Passed: Building - Final Need Picture Of Straps And Locking Caps On A/c Condenser Anthony Aslan 4/14/2022