Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 1183 SE ADAMS ST
HIGH SPRINGS, FL 32643
Parcel #: 09983-001
Acres: 2.44
Owner: Culp John W Jr & Tammy
Subdivision: Bicentennial Acres Unit One
Zoning: A-3
Flood Zone: X
District: 4
Application #: 49730
Permit #: 000042235
Related Permit:
Submitted: Tuesday, June 29, 2021
Issued: Tuesday, June 29, 2021
Expires: Monday, July 26, 2021
Completed: Monday, July 26, 2021
Status: Completed
Septic Release? na
Notes:
AFFIDAVIT REC'D
Job Details
Finished floor requirement
Fema map number 12023C0514C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 4030
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL18355-R6
Product Manufacturer TAMKO
Product Description SHINGLES
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Sealed roof decking explanation for other option. Peel and stick underlayment
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Second Roof Pitch (if applicable) 2:12 to 4:12
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
6/23/2021 Application pending.
6/24/2021 Final Review - Corrections Needed *PLESE LIST THE NAME OF THE CONTRACTOR OR THE QUALIFED AGENT AS THE APPLICANT AND PROVIDE CORRESPONDING ADDRESS AND PHONE NUMBER INFORMATION-- NOT THE HOMEOWNER OR COMPANY INFO *PLEASE LIST THE OWNERS PHONE NUMBER-- NOT THE COMPANIES, ALSO, PLEASE PROVIDE OWNER EMAIL IF APPLICABLE, OR LEAVE BLANK, DO NOT FILL WITH CONTRACTOR EMAIL *OWNER AND CONTRACTOR SIGNATURE PAGE IS NOT SIGNED BY CONTRACTOR NOR NOTARIZED. PLEASE CORRECT.
6/29/2021 Final Review - Payment Needed
6/29/2021 Permit Issued Permit #000042235 created and approved.
Contractors
Name/ Business License Title Role
Michael Douglass
Douglass Restoration Inc
CCC1330263 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 7/15/2021
Passed: Re-Roof - Final Anthony Aslan 7/26/2021