Permit Details

Permit Search

Permit

Storage Building

200 SW ORANGE BLOSSOM CT
LAKE CITY, FL 32025

Permit #
000042209
Application #
49626
Status Completed
  1. Submitted —
  2. Issued Jun 24, 2021
  3. Expires Mar 13, 2022
  4. Completed Sep 14, 2021

Property

Parcel #
02941-128
Owner
Dutton Randell L
Acres
0.74
Subdivision
Southern Landings Aviation
Zoning
RSF-2
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Accessory Use
Finished floor requirement
Non-Habitable Structure
Fema map number
12023C0293D
In floodway
N
Type of Structure
Garage
Commercial or Residential?
Residential
Total Area (Sqft)
768
Septic# (00-0000) or (X00-000)
21-0548
Setbacks Front
25'
Setback Side 1
10'
Setback Side 2
10'
Setback Rear
15'
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Storage
Occupancy Use Title
non habitable vehicle storage
Dev Permit #
F023-
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Building Height
17.11'
Building Length
24
Building Width
32

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Zoning Review - Reviewed
  4. Plan Review - Electrical Approved
  5. Plan Review - Building Approved
  6. Plan Review - Reviewed
  7. Zoning Review - Reviewed
  8. Final Review - Reviewed
  9. Final Review - Payment Needed
  10. Permit Issued

Contractors

This is an owner-builder project.

Inspections

  1. Jun 23, 2021

    Septic Release Inspection

    Inspected by Health Dept

  2. Jun 30, 2021

    Passed: Building - Slab

    Fibermesh Concrete Will Be Used Also Bait System Will Be Used For Termites

    Inspected by Matt Forsyth

  3. Jul 1, 2021

    Passed: Building - Slab

    Inspected by Matt Forsyth

  4. Aug 18, 2021

    Failed: Building - Roof Decking

    Roof Decking Not Started Wall Sheathing Needs To Have All Shiners Removed That Missed Framing Members And Re Nailed

    Inspected by Matt Forsyth

  5. Aug 20, 2021

    Rescheduled 8/23/2021:Building - Roof Decking

    Inspected by Matt Forsyth

  6. Aug 23, 2021

    Failed: Building - Roof Decking

    Nail Off Is 4 Inches Perimeter 8 Inches In The Field

    Inspected by Matt Forsyth

  7. Aug 24, 2021

    Passed: Building - Roof Decking

    Inspected by Matt Forsyth

  8. Aug 24, 2021

    Passed: Building - Wall Sheathing

    Inspected by Matt Forsyth

  9. Aug 25, 2021

    Cancelled: Building - Roof Decking

    Inspected by Matt Forsyth

  10. Aug 25, 2021

    Cancelled: Building - Wall Sheathing

    Inspected by Matt Forsyth

  11. Aug 26, 2021

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  12. Sep 14, 2021

    Passed: Building - Final

    Inspected by Matt Forsyth