Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Screen Enclosure Permit

Address 311 NW CASTLEWOOD CT
LAKE CITY, FL 32055
Parcel #: 01777-103
Acres: 5.01
Owner: Haffner David & Patricia
Subdivision: Suwannee Valley Farms Phase 1
Zoning: A-3
Flood Zone: X
District: 1
Application #: 49550
Permit #: 000042167
Related Permit:
Submitted: Tuesday, June 8, 2021
Issued: Thursday, June 17, 2021
Expires: Tuesday, July 6, 2021
Completed: Tuesday, July 6, 2021
Status: Completed
Septic Release? na
Notes:
POOL PERMIT #41768
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 1' above the crown of the road (100.99')
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0289D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 2052
Total Area (Sqft) 2622
Building Height 21
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0214
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
6/7/2021 Application pending.
6/9/2021 Point Review - On Hold-Incomplete PLEASE UPLOAD ALL NECESSARY DOCUMENTS-- MG
6/17/2021 Application Converted Application was converted from Additions to Screen Enclosure
6/17/2021 Plan Review - Building Approved
6/17/2021 Plan Review - Reviewed
6/17/2021 Zoning Review - Reviewed
6/17/2021 Final Review - Payment Needed
6/17/2021 Permit Issued Permit #000042167 created and approved.
Contractors
Name/ Business License Title Role
Amy B Timberlake
Timberlake Aluminum Construction Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
SCC131150882 Cert Specialty Structure Contractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Screen Enclosure Final Troy Crews 7/6/2021
Documents
File Name Date File Size