Permit Details

Permit Search

Permit

Additions

313 SW WINDSWEPT GLN
LAKE CITY, FL 32024

Permit #
000041978
Application #
48785
Status Completed
  1. Submitted —
  2. Issued May 21, 2021
  3. Expires Sep 3, 2022
  4. Completed Mar 3, 2022

Property

Parcel #
03120-403
Owner
Huber Investments, Llc
Acres
4.17
Subdivision
Windswept Industrial Unit 4
Zoning
ILW
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Site & Development Plan
Finished floor requirement
103.7'
Requirement needed
By Nailing Inspection
Document needed is
a Surveyor letter giving the Finished Floor Elevation
Document receieved
Yes
Fema map number
12023C0381D
In floodway
N
Is this an addition for commercial or residential use?
Commercial
Description of addition:
metal building-warehouse storage
Total Estimated Cost
160000
Heated Area (Sqft)
0
Total Area (Sqft)
6750
Stories
1
Building Height
25
Select driveway access to property:
Existing Drive
Fire sprinklers?
No
Building Code Occupancy Types
Storage
Building Code Element
B
Occupancy Use Title
COMMERCIAL STORAGE
Setbacks Front
20'
Setback Side 1
15'
Setback Side 2
15'
Setback Rear
15'
Septic#
X21
Dev Permit #
F023-
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Sealed roof decking options. (Must select one.)
Other (explain)
Sealed roof decking explanation for other option.
NA/METAL BLDG

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Point Review - Reviewed
  3. Zoning Review - Reviewed
  4. Plan Review - Documents Required
  5. Plan Review - Documents Required
  6. Plan Review - Documents Required
  7. Plan Review - Documents Required
  8. Plan Review - Reviewed
  9. Zoning Review - Reviewed
  10. Application Converted
  11. Final Review - Reviewed
  12. Permit Issued

Contractors

  • David Simque

    Simque Construction Llc

    License
    CGC1516165
    Title
    General Contractor
    Role
    Contractor

    County License & State License & Liability Insurance Expired.

Inspections

  1. May 11, 2021

    Passed: Fire - Plan Review

    Inspected by Tad Cervantes

  2. Jun 15, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  3. Oct 8, 2021

    Failed: Building - Final

    Need To Complete Mounting Of Steps West Side, Label All Electric Panels, Get All Exit Lights Working , Check For Loose Bolts At Feet Of Red Iron, Also Need Fire And Zoning Finals Requested.

    Inspected by Troy Crews

  4. Mar 2, 2022

    Passed: Building - Final

    Need Fire And Zoning Final For C.o.

    Inspected by Troy Crews

  5. Mar 3, 2022

    Passed: Engineering - Zoning Final

    Inspected by Brandon Stubbs

  6. Mar 7, 2022

    Passed: Fire - Fire Final

    Inspected by Lance Hill