Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 244 SW BEACON WAY
LAKE CITY, FL 32025
Parcel #: 02951-106
Acres: 0.49
Owner: Pfs Solutions, Inc
Subdivision: Amelia Landing Phase 1
Zoning: PRD
Flood Zone: X
District: 5
Application #: 49090
Permit #: 000041909
Related Permit:
Submitted: Tuesday, April 20, 2021
Issued: Thursday, May 13, 2021
Expires: Wednesday, November 23, 2022
Completed: Wednesday, November 23, 2022
Status: Completed
Septic Release? Yes
Notes:
ELEVATION CONFIRMATION REC'D @ 116.10'
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 116'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0293D
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1638
Total Area (Sqft) 2444
Building Height 21
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) x-city
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Review Notes
Contractors
Name/ Business License Title Role
Robert S Stewart
Pfs Solutions Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CBC1252898 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Stephen M Brisbois
Epic Ac Service (dba) Central Home Heating & Air Llc
CAC1819412 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Documents
File Name Date File Size