Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 279 SW STONEHENGE LN
LAKE CITY, FL 32024
Parcel #: 03099-228
Acres: 0.51
Owner: Conner James
Subdivision: Stonehenge Phase 2
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 49106
Permit #: 000041877
Related Permit: Culvert: 000041878
Submitted: Friday, October 22, 2021
Issued: Tuesday, May 11, 2021
Expires: Tuesday, December 28, 2021
Completed: Tuesday, December 28, 2021
Status: Completed
Septic Release? Yes
Notes:
ENGINEER MINIMUM FINISHED FLOOR ELEVATION LETTER PROVIDED BEFORE PERMITTED ELEVATION CONFIRMATION REC'D @ 99.3'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1762
Total Area (Sqft) 2557
Stories 1
Building Height 15
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 25'
Setback Side 1 25'(2ND front)
Setback Side 2 10'
Setbacks Rear 10'(side)
Septic# (00-0000) or (X00-000) 21-0374
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Engineers Elevation Letter
Finished floor requirement 97.10'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0293D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
4/22/2021 Point Review - Received-Hard Copy Application
4/23/2021 Zoning Review - Reviewed NEEDED: CERT. OF LIABILITY ON JOHN NORRIS CONSTR. CERT. OF LIABILITY ON TOUCHTON'S HTG & AIR. CITY WATER LETTER EH
5/4/2021 Plan Review - Reviewed NEEDED: CERT. OF LIABILITY ON TOUCHTON'S HTG & AIR. CITY WATER LETTER EH
5/10/2021 Point Review - Received-Hard Copy Application NEEDED: CERT. OF LIABILITY ON TOUCHTON'S HTG & AIR. CITY WATER LETTER EH
5/10/2021 Zoning Review - Reviewed NEEDED: CITY WATER LETTER EH
5/10/2021 Final Review - Documents Required NEEDED: CITY WATER LETTER EH
5/11/2021 Permit Issued Permit #000041877 created and approved.
10/22/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Sara E Gresham
John Norris Construction, Llc
CRC1331978 Cert. Residential Contractor
Don C Bills Sr
Hometown Plumbing Services Llc
Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1428890 Plumbing Contractor Subcontractor
Jan R Touchton
Touchton's Heating & Air Conditioning Inc
Liability Insurance & Employees Workers Comp Expired.
CAC058747 Cert. A/c Class “a” Subcontractor
Donald R Hollingsworth
Holly Electric Inc
EC13005429 Electrical Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 5/12/2021
Passed: Electrical - Temporary Service Matt Forsyth 5/17/2021
Release to power company Matt Forsyth 5/17/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 5/19/2021
Passed: Building - Monolithic Slab Matt Forsyth 5/28/2021
Passed: Engineering - Setbacks Matt Forsyth 5/28/2021
Passed: Building - Roof Decking Matt Forsyth 7/6/2021
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 7/19/2021
Passed: Building - Framing Matt Forsyth 8/24/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 8/24/2021
Passed: Mechanical - Rough In Matt Forsyth 8/24/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 8/24/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Matt Forsyth 8/24/2021
Passed: Building - Insulation Matt Forsyth 9/7/2021
Passed: Engineering - Final Driveway Jones, Richard 10/22/2021
Passed: Electrical - Permanent Power Need Septic Final Troy Crews 10/22/2021
Septic Release Inspection Health Dept 10/26/2021
Release to power company Melissa Garber 10/29/2021
Passed: Building - Final Matt Forsyth 12/28/2021
Documents
File Name Date File Size
Product Approval Code Specifications Form 20210526 104146.pdf 2023.12.24 332.66kB
1407_0compaction01 2021-05-18 13.17.54.452.pdf 2023.12.24 85.05kB
Septic Approval Paperwork 20210526 104046.pdf 2023.12.24 488.02kB
911 Address Form 20210526 104047.pdf 2023.12.24 214.07kB
Residential Or Commercial Checklist 20210526 104147.pdf 2023.12.24 2.18MB
City Or County Utility Availability Letter 20210526 104048.pdf 2023.12.24 268.46kB
Certificate Of Occupancy 20211228.pdf 2023.12.24 69.05kB
Win_20211223_14_54_09_pro 2021-12-23 15.04.27.376.jpg 2023.12.24 183.60kB
Engineer Letter For Elevation.pdf 2023.12.24 361.31kB
Truss Engineering 20210526 104747.pdf 2023.12.24 13.64MB
Win_20210528_10_41_56_pro 2021-05-28 10.42.52.31.jpg 2023.12.24 200.48kB
Power Release-release To Power Company 20211029.pdf 2023.12.24 38.94kB
Manual J Forms 20210526 104346.pdf 2023.12.24 1.26MB
1407_0compaction01 2021-05-18 13.18.40.626.pdf 2023.12.24 85.05kB
Win_20210528_10_41_44_pro 2021-05-28 10.43.41.955.jpg 2023.12.24 297.19kB
Win_20211223_14_53_49_pro 2021-12-23 15.04.05.126.jpg 2023.12.24 121.47kB
Energy Code Forms 20210526 104250.pdf 2023.12.24 3.32MB
Subcontractor Form 20210526 103848.pdf 2023.12.24 302.42kB
Structural Engineering And Wind Load Calculations 20210526 104246.pdf 2023.12.24 2.04MB
Application Information Page 20210526 103850.pdf 2023.12.24 373.17kB
Surveyor Letter Giving The Finished Floor Elevation 2021-07-02 15.10.07.134.pdf 2023.12.24 17.08kB
Plans 2021-05-14 12.48.57.197.pdf 2023.12.24 2.93MB
Lidar 49106 2021-04-23 10.30.42.881.pdf 2023.12.24 116.11kB
Recorded Noc 49106 2021-05-04 14.33.08.871.pdf 2023.12.24 52.26kB
Power Release-electrical-temporary Service 20210517.pdf 2023.12.24 38.80kB
Owner And Contractor Signature Page 20210526 103849.pdf 2023.12.24 450.56kB
Property Appraiser Parcel Details Printed Page 20210526 103946.pdf 2023.12.24 437.10kB
Site Plan 20210526 104047.pdf 2023.12.24 201.53kB
Original Permit 20210511.pdf 2023.12.24 43.25kB