Permit Details

Permit Search

Permit

New Residential Construction

141 SW YULAN ST, UNIT 100 & 102
FORT WHITE, FL 32038

Permit #
000041819
Application #
48947
Status Completed
  1. Submitted Dec 29, 2021
  2. Issued Apr 28, 2021
  3. Expires Jul 5, 2022
  4. Completed Jan 6, 2022

Property

Parcel #
14448-000
Owner
Crb Investments Properties Llc
Acres
1.01
Subdivision
Town Of Fort White
Zoning
RSF-2
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
TOWN OF FORT WHITE REQUIREMENTS
Fema map number
12023C0490C
This is the construction of a
Duplex
Setbacks Front
FW-25'
Setback Side 1
FW-10'
Setback Side 2
FW-10'
Setbacks Rear
FW-15'
Stories
1
Heated Area (Sqft)
2006
Total Area (Sqft)
2188
Building Height
16
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
multi family
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0169
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Final Review - Documents Required
  3. Zoning Review - Reviewed
  4. Plan Review - Reviewed
  5. Final Review - Documents Required
  6. Final Review - Reviewed
  7. Final Review - Payment Needed
  8. Permit Issued
  9. Final Review - Payment Needed

Contractors

  • James Lipscomb

    Lipscomb & Eagle Development Inc

    License
    CBC1253543
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp Expired.

  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Anthony R Franks

    Franks & Lane Heating And Air Llc

    License
    CAC1818631
    Title
    Cert. A/c Class “b”
    Role
    Subcontractor

    County License & State License Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. Jul 9, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Anthony Aslan

  2. Jul 14, 2021

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  3. Jul 14, 2021

    Failed: Building - Monolithic Slab

    Not Complete, Missing Rebar At Front Porch And Main Slab.

    Inspected by Anthony Aslan

  4. Jul 14, 2021

    Passed: Engineering - Setbacks

    Inspected by Anthony Aslan

  5. Jul 14, 2021

    Passed: Building - Monolithic Slab

    Recv'd Picture Of Rebar

    Inspected by Anthony Aslan

  6. Aug 10, 2021

    Passed: Electrical - Temporary Service

    Corrected Permit Number Of Inspection Request.

    Inspected by Anthony Aslan

  7. Aug 10, 2021

    Release to power company

    Inspected by Anthony Aslan

  8. Aug 31, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Sheathing Good Cut Wrap In Places. Need Detail Showing Screws For Porch Post To Beam Connection.

    Inspected by Anthony Aslan

  9. Sep 28, 2021

    Cancelled: Building - Ext Strapping/Wall Sheathing

    Inspected by Anthony Aslan

  10. Sep 28, 2021

    Cancelled: Building - Wall Sheathing

    Inspected by Anthony Aslan

  11. Sep 28, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  12. Sep 28, 2021

    Failed: Building - Framing

    Right Unit Missing Anchor At Bottom Plate Splice. right Unit Nails Missing On Truss Strap Front Room missing Lsta30 On Gables Gable Detail On Plans

    Inspected by Anthony Aslan

  13. Sep 28, 2021

    Failed: Building - Strapping

    Need Letter For Post Screws

    Inspected by Anthony Aslan

  14. Oct 27, 2021

    Passed: Building - Framing

    Inspected by Anthony Aslan

  15. Oct 27, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  16. Oct 27, 2021

    Passed: Mechanical - Rough In

    Inspected by Anthony Aslan

  17. Oct 27, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Anthony Aslan

  18. Oct 27, 2021

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    No Water In Shower Pans

    Inspected by Anthony Aslan

  19. Nov 2, 2021

    Passed: Building - Insulation

    Walls Only

    Inspected by Anthony Aslan

  20. Dec 6, 2021

    Passed: Electrical - Permanent Power

    Need Septic ? Driveway

    Inspected by Anthony Aslan

  21. Dec 29, 2021

    Release to power company

    Inspected by Anthony Aslan

  22. Dec 29, 2021

    Cancelled: Building - Final

    Inspected by Anthony Aslan

  23. Dec 29, 2021

    Septic Release Inspection

    Inspected by Health Dept

  24. Jan 6, 2022

    Passed: Building - Final

    Inspected by Anthony Aslan

Documents