Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 260 NW WHITTON CT
LAKE CITY, FL 32055
Parcel #: 02202-119
Acres: 11.59
Owner: Brown Road Properties Llc
Subdivision: High Pointe
Zoning: PRRD
Flood Zone: X
District: 3
Application #: 48688
Permit #: 000041776
Related Permit: Culvert Waiver: 000041777
Submitted: Wednesday, March 10, 2021
Issued: Wednesday, April 21, 2021
Expires: Wednesday, November 10, 2021
Completed: Wednesday, November 10, 2021
Status: Completed
Septic Release? Yes
Notes:
IF MINIMUM ELEVATION OF 1' ABOVE THE ROAD CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED TO DETERMINE THE MFE.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 3003
Total Area (Sqft) 4159
Stories 2
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 35' Wetland & 200' Buffer
Septic# (00-0000) or (X00-000) 21-0342
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0280D
In floodway N
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
3/10/2021 Application pending.
3/10/2021 Point Review - Printed-Online Application
3/15/2021 Zoning Review - Reviewed CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/23/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/25/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/25/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/30/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
4/6/2021 Plan Review - Reviewed CULLY: ENERGY CODE- REC'D MANUAL "J"- REC'D EH SEALED WINDLOAD/ENG- REC'D
4/21/2021 Zoning Review - Reviewed
4/21/2021 Final Review - Payment Needed
4/21/2021 Permit Issued Permit #000041776 created and approved.
10/25/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Failed: Building - Footer Need Compaction Test On Footing, Rec'd And Uploaded Sdt Matt Forsyth 4/29/2021
Passed: Engineering - Setbacks Matt Forsyth 4/29/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 5/26/2021
Passed: Building - Footer Matt Forsyth 5/27/2021
Passed: Engineering - Setbacks Matt Forsyth 5/27/2021
Passed: Building - Slab Troy Crews 6/2/2021
Passed: Electrical - Temporary Service Matt Forsyth 6/21/2021
Release to power company Matt Forsyth 6/21/2021
Passed: Building - Roof Decking Matt Forsyth 7/16/2021
Passed: Building - Wall Sheathing Matt Forsyth 7/16/2021
Passed: Building - Framing Matt Forsyth 9/1/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 9/1/2021
Passed: Mechanical - Rough In Matt Forsyth 9/1/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 9/1/2021
Passed: Building - Insulation Walls And Vaulted Ceiling Matt Forsyth 9/9/2021
Septic Release Inspection Health Dept 9/10/2021
Passed: Electrical - Permanent Power Matt Forsyth 10/27/2021
Release to power company Matt Forsyth 10/27/2021
Passed: Building - Insulation Ceiling Matt Forsyth 11/10/2021
Passed: Building - Final Matt Forsyth 11/10/2021
Documents
File Name Date File Size
Owner And Contractor Signature Page 20210310 161556.pdf 2023.12.24 1.16MB
Original Permit 20210421.pdf 2023.12.24 43.06kB
Recorded Notice Of Commencement 20210422 115657.pdf 2023.12.24 684.85kB
Sealed S4.pdf 2023.12.24 785.55kB
Corporate Articles Listing The Owner Or Poa Form Or Executor Documents 20210311 092346.pdf 2023.12.24 372.43kB
Win_20211015_11_43_19_pro 2021-11-10 10.27.03.62.jpg 2023.12.24 133.90kB
Win_20211110_10_24_43_pro 2021-11-10 10.26.10.417.jpg 2023.12.24 210.32kB
Architectural Plans 20210310 161917.pdf 2023.12.24 5.96MB
Power Release-electrical-permanent Power 20211027.pdf 2023.12.24 38.98kB
Lidar 48688 2021-03-15 17.00.11.117.pdf 2023.12.24 101.11kB
Sealed S1.pdf 2023.12.24 939.50kB
High Pointe Lot 19 2021-04-21 14.05.29.163.pdf 2023.12.24 639.01kB
Win_20210602_11_15_30_pro 2021-06-02 11.26.53.773.jpg 2023.12.24 215.12kB
Approved Truss Plans 48688 2021-03-23 07.47.26.320.pdf 2023.12.24 1.16MB
Win_20211110_10_24_43_pro 2021-11-10 10.41.20.96.jpg 2023.12.24 210.32kB
Soil Density Test 41776 2021-05-27 08.12.17.768.pdf 2023.12.24 91.42kB
Truss Engineering 20210312 160856.pdf 2023.12.24 1.03MB
Sealed S3.pdf 2023.12.24 1.78MB
High_pointe Lot 19 2021-04-21 15.25.11.378.pdf 2023.12.24 7.06MB
Site Plan 20210310 161920.pdf 2023.12.24 92.38kB
Energy Code Forms 20210401 172732.pdf 2023.12.24 59.79kB
911 Address Form 20210310 161917.pdf 2023.12.24 246.28kB
Certificate Of Occupancy 20211110.pdf 2023.12.24 69.03kB
Property Appraiser Parcel Details Printed Page 20210310 161919.pdf 2023.12.24 588.88kB
Approved Truss Plans 48688 2021-04-06 14.55.09.230.pdf 2023.12.24 1.16MB
Residential Or Commercial Checklist 20210310 161919.pdf 2023.12.24 821.17kB
Subcontractor Form 20210310 161920.pdf 2023.12.24 782.30kB
Recorded Deed 20210310 113746.pdf 2023.12.24 1.19MB
Product Approval Code Specifications Form 20210310 161919.pdf 2023.12.24 748.01kB
Manual J Forms 20210401 172733.pdf 2023.12.24 377.76kB
Power Release-electrical-temporary Service 20210621.pdf 2023.12.24 38.84kB
Sealed S2.pdf 2023.12.24 1.17MB