Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 260 NW WHITTON CT
LAKE CITY, FL 32055
Parcel #: 02202-119
Acres: 11.59
Owner: Brown Road Properties Llc
Subdivision: High Pointe
Zoning: PRRD
Flood Zone: X
District: 3
Application #: 48688
Permit #: 000041776
Related Permit: Culvert Waiver: 000041777
Submitted: Wednesday, March 10, 2021
Issued: Wednesday, April 21, 2021
Expires: Wednesday, November 10, 2021
Completed: Wednesday, November 10, 2021
Status: Completed
Septic Release? Yes
Notes:
IF MINIMUM ELEVATION OF 1' ABOVE THE ROAD CANNOT BE MET THEN AN ENGINEER LETTER WILL BE REQUIRED TO DETERMINE THE MFE.
Job Details
Finished floor requirement
Fema map number 12023C0284D
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure Commercial Building
Commercial or Residential Commercial
Roof Area (for this job) Sq Ft 165.88
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL 10124.1
Product Manufacturer GAF
Product Description Timberline HDZ Asphalt Shingles
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Review Notes
3/10/2021 Application pending.
3/10/2021 Point Review - Printed-Online Application
3/15/2021 Zoning Review - Reviewed CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/23/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/25/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/25/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
3/30/2021 Plan Review - Documents Required CULLY: ENERGY CODE MANUAL "J" EH SEALED WINDLOAD/ENG
4/6/2021 Plan Review - Reviewed CULLY: ENERGY CODE- REC'D MANUAL "J"- REC'D EH SEALED WINDLOAD/ENG- REC'D
4/21/2021 Zoning Review - Reviewed
4/21/2021 Final Review - Payment Needed
4/21/2021 Permit Issued Permit #000041776 created and approved.
10/25/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Failed: Building - Footer Need Compaction Test On Footing, Rec'd And Uploaded Sdt Matt Forsyth 4/29/2021
Passed: Engineering - Setbacks Matt Forsyth 4/29/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 5/26/2021
Passed: Building - Footer Matt Forsyth 5/27/2021
Passed: Engineering - Setbacks Matt Forsyth 5/27/2021
Passed: Building - Slab Troy Crews 6/2/2021
Passed: Electrical - Temporary Service Matt Forsyth 6/21/2021
Release to power company Matt Forsyth 6/21/2021
Passed: Building - Roof Decking Matt Forsyth 7/16/2021
Passed: Building - Wall Sheathing Matt Forsyth 7/16/2021
Passed: Building - Framing Matt Forsyth 9/1/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 9/1/2021
Passed: Mechanical - Rough In Matt Forsyth 9/1/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 9/1/2021
Passed: Building - Insulation Walls And Vaulted Ceiling Matt Forsyth 9/9/2021
Septic Release Inspection Health Dept 9/10/2021
Passed: Electrical - Permanent Power Matt Forsyth 10/27/2021
Release to power company Matt Forsyth 10/27/2021
Passed: Building - Insulation Ceiling Matt Forsyth 11/10/2021
Passed: Building - Final Matt Forsyth 11/10/2021