Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 260 SW PAISLEY CT
FORT WHITE, FL 32038
Parcel #: 04060-133
Acres: 0.49
Owner: Lisa's Land Llc
Subdivision: Fort White Park
Zoning: FORT WHITE
Flood Zone: X
District: 2
Application #: 48588
Permit #: 000041729
Related Permit:
Submitted: Monday, January 24, 2022
Issued: Tuesday, April 13, 2021
Expires: Monday, July 11, 2022
Completed:
Status: Final Review - Payment Needed
Septic Release? Yes
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0383D
Type Roofing Job Replacement - Tear off Existing and Replace
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Yes the existing shingles are being removed and replaced
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 44
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number 18355.1
Product Manufacturer TAMKO Asphalt Shingles
Product Description ASTM D3462 asphalt shingles and hip and ridge shingles
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Ventilation: Ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
3/2/2021 Point Review - Received-Hard Copy Application
3/2/2021 Zoning Review - Complete
3/3/2021 Final Review - Documents Required
3/5/2021 Plan Review - Documents Required
3/9/2021 Plan Review - Documents Required
3/16/2021 Final Review - Documents Required
3/25/2021 Final Review - Documents Required
3/25/2021 Final Review - Payment Needed
4/13/2021 Permit Issued
8/30/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Gary Newsome
G-n Constructioncompany Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CBC1250895 Cert. Build.contractor Contractor
Robert Ogles Ii
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Gary D Newsome
G - N Construction Company Inc
County License & State License & Liability Insurance & Workers Comp Expired.
RF0060370 Reg. Plumbing Subcontractor
Arthur (paul) P King Jr
Pauls Heating & Air Inc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CAC1813957 Cert Class B A/c Subcontractor
Steve M Reeder
Mid Florida Construction & Company Llc
County License & State License & Liability Insurance & Workers Comp Expired.
CBC1257698 Cert. Building Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 5/25/2021
Passed: Building - Slab Anthony Aslan 5/27/2021
Passed: Building - Wall Sheathing Anthony Aslan 6/14/2021
Passed: Building - Roof Decking Anthony Aslan 6/30/2021
Failed: Building - Framing A02, A03 Missing Web Engineering, Need Letter From Engineer For 2" Washers On Anchors, Plans Call For 3" Washers. Anchors At Plate Splices. Anthony Aslan 7/27/2021
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 7/27/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 7/27/2021
Failed: Mechanical - Rough In Missing Strap On Exhaust Duct, Foam Gasket Master Bedroom, Plenum Needs 4" Inch Min Clearance. Anthony Aslan 7/27/2021
Passed: Building - Framing Anthony Aslan 7/29/2021
Passed: Mechanical - Rough In Anthony Aslan 7/29/2021
Cancelled: Mechanical - Rough In Anthony Aslan 7/30/2021
Passed: Building - Insulation Anthony Aslan 8/2/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Master Shower Pan Anthony Aslan 8/25/2021
Septic Release Inspection Health Dept 8/31/2021
Passed: Electrical - Permanent Power Anthony Aslan 8/31/2021
Release to power company Anthony Aslan 8/31/2021
Release to power company Re-released Due To Duke Saying Not Rec'd Melissa Garber 9/9/2021
Passed: Building - Final Need Hose Bib Back Flow, Washer Outlet Not Gfci Anthony Aslan 1/12/2022