Permit Details

Permit Search

Permit

New Residential Construction

384 SW HAPPY JACK DR
LAKE CITY, FL 32024

Permit #
000041726
Application #
48710
Status Completed
  1. Submitted Apr 12, 2022
  2. Issued Apr 12, 2021
  3. Expires Oct 11, 2022
  4. Completed Apr 14, 2022

Property

Parcel #
00415-103
Owner
Eggen Joseph A & Burnett Jenelle L
Acres
10.03
Subdivision
Southwest Estates Unr
Zoning
A-3
Flood zone
X
District
2

Permit

Status
Completed
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0360C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Stories
2
Heated Area (Sqft)
2945
Total Area (Sqft)
5119
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0327

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Zoning Review - Reviewed
  3. Plan Review - Documents Required
  4. Plan Review - Documents Required
  5. Plan Review - Documents Required
  6. Plan Review - Reviewed
  7. Zoning Review - Reviewed
  8. Final Review - Documents Required
  9. Final Review - Payment Needed
  10. Permit Issued

Contractors

  • Guy N Williams

    Slk Construction Inc

    License
    CBC050690
    Title
    Building Contractor
    Role
    Contractor

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

  • Donald R Hollingsworth

    Holly Electric Inc

    License
    EC13005429
    Title
    Electrical
    Role
    Subcontractor
  • Harry D Moseley Sr

    Harry's Heating & Air Conditioning Inc

    License
    RA0030316
    Title
    Class A A/c Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Darin L Summerlin

    Summerlin Roofing Inc

    License
    CCC1326192
    Title
    Roofing Contractor
    Role
    Subcontractor

Inspections

  1. May 6, 2021

    Passed: Electrical - 1st Underground Rough–In

    Inspected by Matt Forsyth

  2. May 6, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Matt Forsyth

  3. May 12, 2021

    Cancelled: Building - Footer

    Inspected by Matt Forsyth

  4. May 12, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  5. May 12, 2021

    Passed: Building - Monolithic Slab

    Main Floor Slab Only

    Inspected by Matt Forsyth

  6. May 12, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  7. May 26, 2021

    Passed: Building - Footer

    Inspected by Matt Forsyth

  8. May 26, 2021

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  9. May 26, 2021

    Passed: Building - Monolithic Slab

    Inspected by Matt Forsyth

  10. Dec 13, 2021

    Cancelled: Electrical - 2nd Rough-In

    Inspected by Melissa Garber

  11. Dec 13, 2021

    Cancelled: Plumbing/Gas - 2nd Rough-In

    Inspected by Melissa Garber

  12. Dec 13, 2021

    Cancelled: Building - Framing

    Inspected by Melissa Garber

  13. Dec 15, 2021

    Passed: Building - Framing

    Inspected by Matt Forsyth

  14. Dec 15, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  15. Dec 15, 2021

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  16. Dec 15, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  17. Jan 13, 2022

    Passed: Building - Insulation

    Garage Wall Will Be Insulated After Sheetrock Is Installed In Garage

    Inspected by Matt Forsyth

  18. Apr 14, 2022

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  19. Apr 14, 2022

    Release to power company

    Inspected by Troy Crews

  20. Apr 14, 2022

    Passed: Building - Final

    Inspected by Troy Crews