Permit Details

Permit Search

Permit

New Residential Construction

908 SW PAUL PEARCE LN
LAKE CITY, FL 32024

Permit #
000041688
Application #
48856
Status Completed
  1. Submitted —
  2. Issued Apr 7, 2021
  3. Expires Apr 2, 2022
  4. Completed Oct 5, 2021

Property

Parcel #
09298-001
Owner
Sullivan Brett And Stephanie
Acres
4.94
Subdivision
—
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0395C
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
2192
Total Area (Sqft)
3158
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000)
21-0266
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.

Status & Review History

  1. Point Review - Received-Hard Copy Application
  2. Zoning Review - Reviewed
  3. Plan Review - Reviewed
  4. Zoning Review - Reviewed
  5. Final Review - Payment Needed
  6. Final Review - Payment Needed
  7. Permit Issued
  8. Final Review - Payment Needed

Contractors

  • Brian T Giebeig

    Trent Giebeig Construction,inc.

    License
    CRC1330693
    Title
    Residential Contractor
    Role
    Contractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Derrick L Williams

    Dl Williams Heating & Cooling Llc

    License
    CAC1816913
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor
  • Kenneth R Roche

    Ken Roche Plumbing Inc Dba Plumbing Now

    License
    CFC1426527
    Title
    Plumbing Contractor
    Role
    Subcontractor

Inspections

  1. Apr 8, 2021

    Passed: Building - Footer

    Inspected by Troy Crews

  2. Apr 8, 2021

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Apr 14, 2021

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  4. Apr 14, 2021

    Release to power company

    Inspected by Troy Crews

  5. Apr 14, 2021

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  6. Apr 16, 2021

    Passed: Building - Slab

    Inspected by Troy Crews

  7. May 28, 2021

    Passed: Building - Roof Decking

    Inspected by Anthony Aslan

  8. May 28, 2021

    Passed: Building - Ext Strapping/Wall Sheathing

    Need Detail For Porch Beam Strapping

    Inspected by Anthony Aslan

  9. Jun 23, 2021

    Passed: Electrical - 2nd Rough-In

    Inspected by Anthony Aslan

  10. Jun 23, 2021

    Failed: Mechanical - Rough In

    Missing Exhaust Duct On Hall Bath exhaust Venting Not Strapped, Missing 181 Tape On Exhaust Fan.

    Inspected by Anthony Aslan

  11. Jun 23, 2021

    Failed: Plumbing/Gas - 2nd Rough-In

    Shower Valves Not Installed

    Inspected by Anthony Aslan

  12. Jun 23, 2021

    Passed: Plumbing/Gas - Tub Set/Shower Pan

    Inspected by Anthony Aslan

  13. Jun 23, 2021

    Passed: Building - Framing

    Inspected by Anthony Aslan

  14. Jun 23, 2021

    Passed: Building - Strapping

    Inspected by Anthony Aslan

  15. Jun 28, 2021

    Passed: Building - Insulation

    Inspected by Troy Crews

  16. Jun 28, 2021

    Passed: Mechanical - Rough In

    Items Corrected

    Inspected by Troy Crews

  17. Jun 28, 2021

    Passed: Plumbing/Gas - 2nd Rough-In

    Completed

    Inspected by Troy Crews

  18. Sep 9, 2021

    Septic Release Inspection

    Inspected by Health Dept

  19. Sep 9, 2021

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  20. Sep 9, 2021

    Release to power company

    Inspected by Troy Crews

  21. Oct 4, 2021

    Passed: Building - Final

    Need Blower Door Test For Release

    Inspected by Troy Crews

  22. Oct 5, 2021

    Certificate-Release Certificate

    Blower Door Received

    Inspected by Troy Crews